Wiring Diagrams - Regency P36E-NG4 Owners & Installation Manual

P36e zero clearance direct vent gas fireplace
Table of Contents

Advertisement

INSTALLATION
This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/
thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.
(Do not cut the ground terminal off under any circumstances.)
NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit)
in case the fan is installed at a later date.
Proflame System
886 ON/OFF Stand Alone
Illustrated Wire Diagram
Standard Main ON/OFF
Switch or Optional Wall Switch
IMPORTANT:
If the optional remote control is used, the AA batteries normally installed into the battery holder must be removed. The AA batteries in the
receiver now operate the unit. Having AA batteries in both the battery holder and receiver will damage the gas valve.
48

WIRING DIAGRAMS

Surefire Switch
(IPI / CPI)
Battery Holder
Proflame System
Configuration
886 GTMF
Wire Diagram
SureFire™ Switch
EI Pilot
886 Proflame Valve
Pilot Ground Wire
Chassis Ground
DFC Wire Harness Assembly
Note: 4 AA batteries must be
installed to operate the burner
switch.
Do not use a 9 volt battery.
P36E-4 Zero Clearance Direct Vent Gas Fireplace
Spark Electrode
Sense Electrode
Proflame DFC Board

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P36e-lp4

Table of Contents