Regency P36E-NG4 Owners & Installation Manual page 26

P36e zero clearance direct vent gas fireplace
Table of Contents

Advertisement

INSTALLATION
One 90
o
elbow = Two 45
Option
V
H
A)
0' Min.
2' Max.
B)
1' Min.
4' Max.
C)
2' Min.
5' Max.
D)
3' Min.
6' Max.
E)
4' Min.
7' Max.
F)
5' Min.
8' Max.
Lengths do not include elbow indicated
For additional vertical venting with 2 x 90
o
One 90
elbow = Two 45
Option
V
H + H1
A)
0' Min.
2' Max.
B)
1' Min.
2' Max
C)
2' Min.
3' Max
D)
3' Min.
4' Max
E)
4' Min.
5' Max
F)
5' Min.
6' Max
G)
6' Min.
7' Max
H)
7' Min.
8' Max
Lengths do not include elbow indicated
26
Vertical Venting with Two (2) 90
o
elbows.
V + V1
With these options,
1' Min.
max. total pipe length
2' Min.
is 30 feet with min.
of 6 feet total vertical
3' Min.
and max. 8 feet total
4' Min.
horizontal.
5' Min.
Please note min. 1
6' Min.
foot between 90
elbows is required.
elbows, refer to next page.
o
Vertical Venting with Three (3) 90
o
elbows.
V + V1
With these options,
2' Min.
max. total pipe length
3' Min.
is 30 feet with min. of
10 feet total vertical
4' Min.
and max. 8 feet total
6' Min.
horizontal.
7' Min.
Please note min. 1
8' Min.
foot between 90
o
elbows is required.
9' Min.
10' Min.
Elbows
o
V1
o
o
Elbows
V1
H1
P36E-4 Zero Clearance Direct Vent Gas Fireplace
V
H
V
H