Removing Valve; Installing Valve - Regency PANORAMA P33E Owners & Installation Manual

Hide thumbs Also See for PANORAMA P33E:
Table of Contents

Advertisement

maintenance
|
52

REMOVING VALVE

1) Shut off the gas and electrical supply.
2) Remove the safety screen.
3) Open and remove the glass door.
4) Remove the logs.
5) Remove the burner/grate assembly by removing the two screws
and then lift the burner assembly out.
Diagram 1: Remove the left and right screws and then lift out the
burner/grate assembly.
6) Disconnect the Electronic modulator, EV1, EV2, and ground wires
from the valve - as shown below.
Electronic Modulator
52 |
Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace
Ground
EV2
EV1
9) Remove the 10 screws securing the valve tray assembly in place
(diagram 2) and then lift the entire assembly out (diagram 3).
screws
Diagram 2: Rear Log Stand & Valve Tray Assembly
10) Remove valve tray assembly.
Diagram 3: Lift out Valve Tray Assembly

INSTALLING VALVE

1) Install new valve assembly.
2) Reverse steps 9 through 1.
Rear Log Stand