Gt Remote Installation - Regency P36E-NG4 Owners & Installation Manual

P36e zero clearance direct vent gas fireplace
Table of Contents

Advertisement

1) Shut off the gas supply and disconnect all power to the unit.
2) Remove the louvers, bay door or faceplate if installed.
3) Disconnect battery pack - located on the fl oor of the unit, as shown
below and discard.
4) Remove DFC (digital fi rebox control box) from the fl oor of the unit.
5)
Disconnect wire harness, ground wire and spark wire from DFC.
See attached wiring diagram for details.
6) Identify wires in the GT remote wiring harness.
(see wiring diagram.)
7) Connect the TPTH and TH wires - green to green and white to
white as shown below. See attached wiring diagram for details.
TPTH
(white)
P36E-4 Zero Clearance Direct Vent Gas Fireplace

GT REMOTE INSTALLATION

8) Plug in receiver DC supply wire - as shown below.
9) Install 4 - AA batteries into the receiver, ensure correct polarity.
10) Plug receiver wires into the back of the receiver and bundle wires
11) Install the heat shield to the receiver with two screws and attach to
TH
12) Reverse steps 5 and 4.
(green)
13) Match the remote control to the receiver - see remote control
14) Reverse steps 2 and 1.
15) Check to ensure there are no gas leaks.
INSTALLATION
with the wire clip as shown below.
the fl oor of the unit with a velcro pad.
instructions.
Wire Clip
Heat Shield