Mounting The Controlwave Efm Enclosure - Emerson ControlWave EFM 4710A Instruction Manual

Emerson electronic flow meter instruction manual

Advertisement

2.3.1 Mounting the ControlWave EFM Enclosure

When mounting one of these units, it is to be positioned in accordance with the following
restrictions:
The unit is to be positioned vertically with the Multivariable Transducer (MVT) at its
-
base and is to be mounted to a wall or a vertical 2" pipe (clamed at the rear of the unit
via two clamps and four bolts). If used, the 2" pipe is to be anchored in cement (deep
enough to conform to local building codes associated with frost considerations). The
basic unit measures 14.55" in height by 13" in width by 6.875" in depth. A Mul-
tivariable Transducer adds 2.8" to the unit's height. See Figures 2-3 and 2-4.
(1) 1" NPT Conduit Hub
(3) RTD Cable Assembly or Sealing Plug
(5) 5" Liquid Tight Conduit Fitting or Plug
(7) Solderless Ground Lug
(8) Multivariable Transducer
-
The Multivariable Transducer (MVT) is bolted to a process manifold which in-turn is
connected to the main (meter run) directly or via two pipes (see Figures 2-5 - 2-7).
The unit must be positioned so that the front of the assembly is visible and the unit is
-
accessible for service, i.e., installing an option or replacement of the Lithium Battery,
or installation/removal of any ControlWave EFM Module.
Make certain that the LCD Display/Keypad is accessible and visible to the on-site
-
operator.
2-8 / Installation & Operation
Figure 2-3 - ControlWave EFM Bottom View
(2) Local Port D-Type Jack
Male D-Type Jack or
Circular Female Jack
(4) Battery Ventilation Assembly
(6) Ant. Cable Fitting, Polyphaser,
or Plug