Special Instructions for Class I, Division 2 Hazardous Locations
Table A1 -Module/Board Connector Customer Wiring Connectors (Continued)
Module/Item
SCM Module
SCM Module
Exp. Comm Module 1
Exp. Comm Module 1
Exp. Comm Module 2
Exp. Comm Module 2
Analog I/O Module
Digital I/O Module
HSC Input Module
Mixed I/O Module
Digital To Relay I/O Bd.
Power Distribution Bd.
(see ¶ 5 - this document)
21V Power Supply Bd.
(see ¶ 5 & 13 of
this document)
Enclosure Bottom
Note: * = These wires should only be installed/removed when the item (PCB) in question is
installed/removed or when checking wiring continuity. The area must be known to be
nonhazardous before servicing/replacing the unit and before installing or removing PCBs,
Connectors or individual I/O or Power wires. Refer to
power and I/O wiring must be performed in accordance with Class I, Division 2 wiring
methods as defined in Article 501-4 (b) of the National Electrical Code, NFPA 70, for
installations within the United States, or as specified in Section 18-152 of the Canadian
Electrical Code for installation in Canada.
10/06/2006
ControlWave EFM
Connector
TB1 - Input Power
TB2 - RTD Interface
J4 - COM4, 9-pin Male D-sub
RS-232
J5 - COM5, 9-pin Male D-sub
RS-485
J8 - COM7, RJ11 Female
J4 - COM8, 9-pin Male D-sub
RS-232
J5 - COM9, 9-pin Male D-sub
RS-485
J8 - COM11, RJ11 Female
TB1/TB2 - 10-pin Term. Blocks
TB1/TB2 - 10-pin Term. Blocks
TB1/TB2 - 10-pin Term. Blocks
TB1/TB2 - 10-pin Term. Blocks
J1 10-pin In-line Connector
TB1 - 3-pin Term Block
TB2 - 2-pin Term Block
TB3 - 2-pin Term Block
TB4 - 2-pin Term Block
TB5 - 2-pin Term Block
TB6 - 2-pin Term Block
TB1 - 3-pin Term Block
TB2 - 4-pin Term Block
Local Port Circular Connector
Appendix A, Document CI-ControlWave EFM
Wiring Notes
Typically Factory Wired - *
Field Wired - Refer to ¶ 9 of this document.
Remote Comm. Port: For Radio or external
Network Comm. Refer to Model Spec. and ¶ 10
of this document. When used for Network
Comm., use Div. 2 wiring methods. If COM4 is
used in conjunction with a radio/modem refer
to 11 of this document.
Modular connection to Phone Co. equipment.
Remote Comm. Port: For Radio or external
Network Comm. Refer to Model Spec. and ¶ 10
of this document. When used for Network
Comm., use Div. 2 wiring methods. If COM8 is
used in conjunction with a radio/modem refer
to 11 of this Document.
Modular connection to Phone Co. equipment.
Refer to ¶ 6, 7, 8 & 11of this document.
Field I/O wiring connectors are unrated; use
Div. 2 wiring methods. *
Field I/O wiring connectors are unrated; use
Div. 2 wiring methods. *
Field Input wiring connectors are unrated;
use Div. 2 wiring methods. *
Field I/O wiring connectors are unrated; use
Div. 2 wiring methods. *
Field I/O wiring connector is unrated, use Div.
2 wiring methods. Refer to ¶ 12 of this
document. *
Primary Power Input - User wired *
Main Power Out 1 - Factory wired *
Main Power Out 2 - Factory wired *
Fused Power Out 1 - Factory wired *
Fused Power Out 2 - Factory wired *
Fused Power Out 3 - Factory wired *
12V Power Input - Factory wired *
21V Transmitter Power -Field Wired
TB2 is unrated, use Div. 2 wiring methods.
Local Comm. Port - Factory Wired. Refer to ¶
3 of this document. *
6, 7 & 8 of this document. All input
Page 2 of 2