Pole Mounting – Aluminum Enclosure
EXPLOSION HAZARD: Ensure the area in which you perform this operation is non-
hazardous. Performing this operation in a hazardous area could result in an explosion.
1.
2.
3.
4.
1
5/16-18 keps stainless steel hex nut
2
5/16-18 x 1.0 LG wire-lockable socket head cap screw
3
Pole mounting bracket
4
2-inch diameter 5/16-18 x 4.0LG U-bolt
6
DANGER
Apply Loctite
#222
®
TM
head cap screws (Item 2).
Attach pole mounting brackets (Item 3) to enclosure using head cap screws (Item 2)
and hex nuts (Item 1). Torque hex nuts to 30 in-lbs (3.4 N m).
Apply Loctite #222 threadlocker sparingly to threads of U-bolts (Item 4).
Use U-bolts (Item 4) to mount enclosure to pole using hex nuts (Item 1). Torque hex
nuts to 30 in-lbs (3.4 N m).