Specifications
5 Volts/meter @ 100 MHz.
The drive functions normally when any exposed metal is subjected to
electrostatic discharge excluding the PCB. This electrostatic discharge must be at
a minimum interval of 30 seconds, either from a 150pF capacitor discharged
through a 150K
resistor or from a 100pF capacitor through a 500k
resistor.
0 – 5kV
Average of <0.3 soft errors per discharge
5 – 10 kV
Average of <1.0 soft errors per discharge
10 – 20 kV
No permanent degradation
The Maxtor Atlas 10K III family of drives meets all specifications with a 6 gauss
field applied in any environment at 100 kHz.