Read Defect Data (12) Command-Data Format - Maxtor ATLAS 10K III Product Manual

Hide thumbs Also See for ATLAS 10K III:
Table of Contents

Advertisement

SCSI Description
The READ DEFECT DATA (12) command directs the drive to report defect
information about the drive's medium. Refer to the FORMAT UNIT command for
information about defects. The data sent to the host in the command's data-in buffer
transfer consists of a four-byte Defect List header (Table 5-144 and Table 5-145),
followed by any Defect Descriptors (Table 5-142 and Table 5-143).
The READ DEFECT DATA (12) Command Descriptor Block is shown in Table 5-
140; the data fields are described in Table 5-141.
T a b l e 5 - 1 4 0 READ DEFECT DATA (12) Command-Data Format
$ K V

$ [ V G
0
1
2 - 5
(MSB)
6 - 9
10
11
5-114
Maxtor Atlas 10K III


Operation Code (B7h)
Reserved
Plist
Allocation Length



Glist
Defect List Format
Reserved
Reserved
Control


(LSB)