Triumph Rocket III Service Manual page 222

Hide thumbs Also See for Rocket III:
Table of Contents

Advertisement

Fuel System/Engine Management
Purge Valve
Fault Code
Possible cause
Action
P0444
Open circuit or short circuit to earth View & note diagnostic tool 'sensor'
data.
Ensure purge valve connector is
secure.
Disconnect ECM
and
proceed to pinpoint test 1
P0445
Short circuit to battery+
Disconnect
purge
valve
and
proceed to pinpoint test 5
Pinpoint Tests
Test
Result
Action
1 Check cable and terminal integrity:
OK
Proceed to test 2
- ECM pin 831
Faulty
Rectify fault, proceed to test 7
2 Check resistance vaiue:
24Qt028Q
Disconnect purge valve and proceed to
test 3
- ECM pin A20 to ECM pin 831
Open circuit
Proceed to test 4
Short circuit
Disconnect purge valve and proceed to
test 5
3 Check cable for short circuit:
OK
Proceed to test 7
- ECM pin 831 to earth
Short circuit
Locate and rectify wiring fault, proceed to
test 7
4 Check cable continuity:
OK
Proceed to test 6
- ECM pin 831 to valve pin 2
Open circuit
Locate and rectify wiring fault, proceed to
- ECM pin A20 to valve pin 1
test 7
5 Check cable for short circuit:
OK
Proceed to test 6
- ECM pin A20 to ECM pin 831
Short circuit
Locate and rectify Wiring fault, proceed to
test 7
6 Check purge valve resistance:
24Q to 28Q
Proceed to test 7
- Valve pin 1 to valve pin 2
Faulty
Renew purge valve, proceed to test 7
7 Reconnect harness, clear fault code and OK
Action complete - quit test
run diagnostic tool function test to
visually verify operation of purge valve
Fault
Contact Triumph service
11.68
Service Manual - Rocket
III
~.

Advertisement

Table of Contents
loading

Table of Contents