Installing An Uplink Module In A J-Ex4200 Switch - Dell PowerConnect J-EX4200 Hardware Manual

Powerconnect j-series ethernet switch
Hide thumbs Also See for PowerConnect J-EX4200:
Table of Contents

Advertisement

Dell PowerConnect J-Series J-EX4200 Ethernet Switch Hardware Guide
Related
Documentation

Installing an Uplink Module in a J-EX4200 Switch

108
Tighten the screw or screws on the fan tray by using the screwdriver.
2.
Figure 40: Installing a Fan Tray in a J-EX4200 Switch
Removing a Fan Tray from a J-EX4200 Switch on page 141
Installing and Removing J-EX4200 Switch Hardware Components on page 105
Cooling System and Airflow in a J-EX4200 Switch on page 24
Field-Replaceable Units in J-EX4200 Switches on page 16
Rear Panel of a J-EX4200 Switch on page 7
If your J-EX4200 switch includes an optional uplink module, you install it in the switch's
front panel. The different types of uplink modules are described in "Uplink Modules in
J-EX4200 Switches" on page 25.
The uplink module in J-EX4200 switches is a hot-removable and hot-insertable unit
(FRU): You can remove and replace it without powering off the switch or disrupting switch
functions.
NOTE:
If you have set an uplink module port as a Virtual Chassis port (VCP),
removing the uplink module breaks the setting. You must reset the port as a
VCP after you replace the module. See the instructions for setting an uplink
module port as a VCP in the Dell PowerConnect J-Series Ethernet Switch
Complete Software Guide for Junos OS at
http://www.support.dell.com/manuals
Before you begin installing an uplink module in a J-EX4200 switch:
Ensure that you have taken the necessary precautions to prevent ESD damage (see
"Prevention of Electrostatic Discharge Damage on J-EX Series Switches" on page 198).
Ensure that you have the following parts and tools available:
.

Advertisement