Sign In
Upload
Manuals
Brands
HP Manuals
Storage
StorageWorks D2700
HP StorageWorks D2700 Manuals
Manuals and User Guides for HP StorageWorks D2700. We have
5
HP StorageWorks D2700 manuals available for free PDF download: Deployment Manual, User Manual, Specifications
HP StorageWorks D2700 User Manual (80 pages)
Brand:
HP
| Category:
Storage
| Size: 3.07 MB
Table of Contents
Table of Contents
3
1 Hardware
7
Overview
7
Small Form Factor Disk Enclosure Chassis
8
Front View
8
Rear View
8
Drive Bay Numbering
8
Large Form Factor Disk Enclosure Chassis
9
Front View
9
Rear View
9
Drive Bay Numbering
9
Disk Drives
11
Disk Drive Leds
11
Disk Drive Blanks
11
Front Status and UID Module
12
Front UID Module Leds
12
Unit Identification (UID) Button
13
Power Supply Module
14
Power Supply LED
14
Fan Module
15
Fan Module LED
15
I/O Module
16
I/O Module Leds
16
Rear Power and UID Module
18
Rear Power and UID Module Leds
18
Unit Identification (UID) Button
19
Power On/Standby Button
19
SAS Cables
20
2 Technical Specifications
21
General Specifications
21
Power and Environmental Specifications
21
3 Installation
23
Installation Overview
23
Required Items
23
Preliminary Tasks
24
Determining Who will Install and Configure the Disk Enclosure
24
Saving the Disk Enclosure Website as a Favorite in Your Browser
24
Confirming Support for Your Hardware and Software Components
24
Signing up to Automatically Receive Advisories, Notices, and Other Messages
25
Confirming Warranty Support and Finding out about Related Services
25
Gathering and Recording Information
26
Planning the Storage Configuration
26
System and Performance Expectations
26
Striping Methods
27
RAID Levels
27
Disk Drive Sizes and Types
28
Spare Disks
28
Array Sizing
28
Preparing the Site
29
Providing Adequate Structural Support for the Floor
29
Providing Adequate Clearance Space and Ventilation
29
Providing Adequate and Redundant Sources of Power
29
Racking the Disk Enclosure
30
Rack Installation Best Practices
30
Racking Procedures
31
Installing Disk Drives
33
Installing 6Gb SAS Controllers and Preparing the Servers
35
Connecting Cables and Power Cords
36
Overview
36
Cabling Best Practices
36
Cabling the Disk Enclosure to the Controller
37
Cabling Cascaded Disk Enclosures
38
Labeling Cables Using Labeling Kit
38
Connecting Power Cords
39
Powering on the Disk Enclosure
40
Power on Best Practices
40
Power on Procedures
40
Verifying the Operating Status of the Devices
41
Verify the Operating Status of the Disk Enclosures
41
Verify the Operating Status of the Servers and SAS Controllers
42
4 Configuration
43
Configuration Overview
43
Configuration Best Practices
43
Supported Software Tools
43
HP Systems Insight Manager
44
HP Array Configuration Utility
45
Option ROM Configuration for Arrays (ORCA)
46
Smart Components for Firmware Updates
46
5 Operation and Management
47
Powering on Disk Enclosures
47
Powering off Disk Enclosures
48
Updating Disk Enclosure Firmware
48
6 Cabling Examples
49
Large Form Factor D2600 Disk Enclosures + Smart Array P411 Controller; Single I/O Path
49
Large Form Factor D2600 Disk Enclosures + Smart Array P411 Controller; Single I/O Path-Maximum Configuration
50
Large Form Factor D2600 Disk Enclosures + Smart Array P212 Controller; Single I/O Path-Maximum Configuration
51
Small Form Factor D2700 Disk Enclosures + Smart Array P411 Controller; Single I/O Path
52
Small Form Factor D2700 Disk Enclosures + Smart Array P411 Controller; Single I/O Path-Maximum Configuration
53
Small Form Factor D2700 Disk Enclosures + Smart Array P212 Controller; Single I/O Path-Maximum Configuration
54
7 Troubleshooting
55
If the Enclosure Does Not Initialize
55
Diagnostic Steps
55
Is the Enclosure Front Fault LED Amber
55
Is the Enclosure Rear Fault LED Amber
56
Is the Power On/Standby Button LED Amber
56
Is the Power Supply LED Amber
56
Is the I/O Module Fault LED Amber
57
Is the Fan LED Amber
57
Recognizing Disk Drive Failure
58
Effects of a Disk Drive Failure
58
Compromised Fault Tolerance
58
Factors to Consider before Replacing Disk Drives
58
Automatic Data Recovery (Rebuild)
59
Time Required for a Rebuild
59
Failure of Another Drive During Rebuild
59
Handling Disk Drive Failures
60
8 Replacement Procedures
61
Customer Self Repair (CSR)
61
Parts-Only Warranty Service
61
Best Practices for Replacing Hardware Components
61
Verifying Component Failure
61
Identifying the Spare Part
62
Replaceable Parts
62
Replacing the Failed Component
62
Replacement Instructions
63
Exploded View
63
9 Support and Other Resources
65
Contacting HP
65
Before You Contact HP
65
HP Contact Information
65
Subscription Service
65
Documentation Feedback
66
Related Information
66
Websites
66
Document Conventions and Symbols
66
Customer Self Repair
67
Rack Stability
67
10 Regulatory Compliance Notices
69
Regulatory Compliance Identification Numbers
69
Federal Communications Commission Notice
69
FCC Rating Label
69
Class a Equipment
69
Modifications
70
Cables
70
Canadian Notice (Avis Canadien)
70
Class a Equipment
70
European Union Notice
70
Japanese Notices
70
VCCI-A Notice
70
Japanese Power Cord Statement
71
Korean Notices
71
Class a Equipment
71
Taiwanese Notices
71
BSMI Class a Notice
71
Chinese Notice
71
Recycling Notices
71
English Notice
71
Bulgarian Notice
72
Czech Notice
72
Danish Notice
72
Dutch Notice
72
Estonian Notice
73
Finnish Notice
73
French Notice
73
German Notice
73
Greek Notice
74
Hungarian Notice
74
Italian Notice
74
Latvian Notice
74
Lithuanian Notice
75
Polish Notice
75
Portuguese Notice
75
Romanian Notice
75
Slovak Notice
76
Spanish Notice
76
Swedish Notice
76
Turkish Notice
76
Index
77
Advertisement
HP StorageWorks D2700 User Manual (76 pages)
StorageWorks Disk Enclosure
Brand:
HP
| Category:
Storage
| Size: 2.52 MB
Table of Contents
Table of Contents
3
1 Hardware
7
Overview
7
Small Form Factor Disk Enclosure Chassis
8
Front View
8
Drive Bay Numbering
8
Rear View
8
Large Form Factor Disk Enclosure Chassis
9
Front View
9
Drive Bay Numbering
9
Rear View
9
Disk Drives
10
Disk Drive Leds
10
Disk Drive Blanks
10
Front Status and UID Module
11
Front UID Module Leds
11
Unit Identification (UID) Button
12
Power Supply Module
12
Power Supply LED
12
Fan Module
13
Fan Module LED
13
I/O Module
14
I/O Module Leds
14
Rear Power and UID Module
16
Rear Power and UID Module Leds
16
Unit Identification (UID) Button
17
Power On/Standby Button
17
SAS Cables
17
2 Technical Specifications
19
Physical Specifications
19
Power and Environmental Specifications
19
3 Deployment Types
21
4 Installation
23
Installation Overview
23
Required Items
23
Preliminary Tasks
24
Determining Who will Install and Configure the Disk Enclosure
24
Confirming Support for Your Hardware and Software Components
24
Signing up to Automatically Receive Advisories, Notices, and Other Messages
25
Confirming Warranty Support and Finding out about Related Services
25
Gathering and Recording Information
25
Planning the Storage Configuration
25
System and Performance Expectations
26
Striping Methods
26
RAID Levels
26
Disk Drive Sizes and Types
27
Spare Disks
27
Array Sizing
28
Preparing the Site
29
Racking the Disk Enclosure
30
Rack Installation Best Practices
30
Racking Procedures
31
Installing Disk Drives in the Enclosure
32
Disk Drive Options
32
Disk Drive Guidelines
32
Installing a Disk Drive
32
Installing SAS Controllers or Controller Enclosures
34
Preparing the Server
34
Connecting SAS Cables and Power Cords
35
Overview
35
Cabling Best Practices
35
Connecting SAS Cables to the Server or Controller Enclosure
36
Connecting SAS Cables to Cascaded Disk Enclosures
37
Connecting Power Cords
38
Powering on the Disk Enclosure
39
Power on Best Practices
39
Power on Procedures
39
Verifying the Operating Status of the Disk Enclosures
40
5 Configuration
41
Configuration Overview
41
Supported Software Tools
41
6 Operation and Management
43
Powering on Disk Enclosures
43
Powering off Disk Enclosures
44
Updating Disk Enclosure Firmware
44
7 Cabling Examples
45
Large Form Factor D2600 Disk Enclosures - Maximum Capacity Configuration
46
Small Form Factor D2700 Disk Enclosures - Maximum Capacity Configuration
47
Dual Domain Example - Best Fault Tolerance Cabling
48
Dual Domain - Best Performance Cabling
49
Dual Domain-Alternative Cabling
50
8 Troubleshooting
51
If the Enclosure Does Not Initialize
51
Diagnostic Steps
51
Is the Enclosure Front Fault LED Amber
51
Is the Enclosure Rear Fault LED Amber
52
Is the Power On/Standby Button LED Amber
52
Is the Power Supply LED Amber
52
Is the I/O Module Fault LED Amber
53
Is the Fan LED Amber
53
Recognizing Disk Drive Failure
54
Effects of a Disk Drive Failure
54
Compromised Fault Tolerance
54
Factors to Consider before Replacing Disk Drives
54
Automatic Data Recovery (Rebuild)
55
Time Required for a Rebuild
55
Failure of Another Drive During Rebuild
55
Handling Disk Drive Failures
56
9 Replacement Procedures
57
Customer Self Repair (CSR)
57
Parts-Only Warranty Service
57
Best Practices for Replacing Hardware Components
57
Verifying Component Failure
57
Identifying the Spare Part
58
Replaceable Parts
58
Replacing the Failed Component
58
Replacement Instructions
59
Exploded View
59
10 Support and Other Resources
61
Contacting HP
61
Before You Contact HP
61
HP Contact Information
61
Subscription Service
61
Documentation Feedback
62
Related Information
62
Websites
62
Document Conventions and Symbols
62
Customer Self Repair
63
Rack Stability
63
11 Regulatory Compliance Notices
65
Regulatory Compliance Identification Numbers
65
Federal Communications Commission Notice
65
FCC Rating Label
65
Class a Equipment
65
Modifications
66
Cables
66
Canadian Notice (Avis Canadien)
66
Class a Equipment
66
European Union Notice
66
Japanese Notices
66
VCCI-A Notice
66
Japanese Power Cord Statement
67
Korean Notices
67
Class a Equipment
67
Taiwanese Notices
67
BSMI Class a Notice
67
Chinese Notice
67
Recycling Notices
67
English Notice
67
Bulgarian Notice
68
Czech Notice
68
Danish Notice
68
Dutch Notice
68
Estonian Notice
69
Finnish Notice
69
French Notice
69
German Notice
69
Greek Notice
70
Hungarian Notice
70
Italian Notice
70
Latvian Notice
70
Lithuanian Notice
71
Polish Notice
71
Portuguese Notice
71
Romanian Notice
71
Slovak Notice
72
Spanish Notice
72
Swedish Notice
72
Turkish Notice
72
Index
73
HP StorageWorks D2700 Deployment Manual (111 pages)
Solutions with 6Gb SAS BL Switches and External SAS Storage Enclosures
Brand:
HP
| Category:
Network Hardware
| Size: 7.96 MB
Table of Contents
Storage Enclosures. (HP P2000 G3 SAS MSA Revision
2
Table of Contents
3
1 Introduction
6
Topics Discussed in this Guide
7
Devices Referred to in this Guide
7
Documents Referred to in this Guide
7
How to Obtain Detailed Information
9
Information Available in Device Websites
9
Information Available in the Bladesystem Technical Resources Website
9
Helpful HP Websites
9
Getting Started
10
2 Device Information
11
HP Bladesystem C-Class Enclosures
11
HP Bladesystem C3000 Enclosure
12
For more Information
12
HP Bladesystem C7000 Enclosure
13
For more Information
13
Important Tips
13
HP Bladesystem C-Class Server Blades
14
Proliant Server Blades
14
For more Information
14
Important Tips
15
HP Smart Array SAS Controllers
16
For more Information
18
Important Tips
18
HP 6Gb SAS BL Switch
20
For more Information
22
Important Tips
22
HP P2000 G3 SAS MSA and MSA 2040 SAS Systems
23
For more Information
25
Important Tips
26
HP MDS600 and D6000 Disk Enclosures
28
For more Information
29
Important Tips
29
HP D2600/D2700 Disk Enclosures
32
For more Information
32
Important Tips
33
HP MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries and 1/8 G2 Tape Autoloader
34
For more Information
34
Important Tips
35
Rack and Power
36
For more Information
36
3 Software Information
37
HP Onboard Administrator
38
HP 6G Virtual SAS Manager
41
MSL 2040 SAS and P2000 G3 SAS MSA Storage Management Utility
42
MSA 2040 SAS or P2000 G3 MSA Command Line Interface
43
HP Array Configuration Utility
44
HP Smart Storage Administrator
45
HP Systems Insight Manager
46
MSL Tape Libraries and 1/8 G2 Tape Autoloader Remote Management Interface
47
HP MSL Tape Libraries and 1/8 G2 Tape Autoloader Operator Control Panel
48
4 High Availability / Dual Domain Information
49
5 Device Relationships and Mapping Information
50
6 Zoning Information
51
Types of Zone Groups
51
Key Zoning Configuration Steps
51
7 Installation Best Practices and Procedures
52
Key Installation Steps
53
Installation Notes and Best Practices
54
Installation Steps
56
8 Maintenance and Troubleshooting
62
Updating Firmware on Solution Devices
62
Updating Firmware on Bladesystem Components and Devices
62
Updating Firmware on HP 6Gb SAS BL Switches
63
Prerequisites
63
Updating HP 6Gb SAS BL Switch Firmware in Single-Domain Deployments
63
Updating HP 6Gb SAS BL Switch Firmware in Dual-Domain Deployments
65
Revision
67
Updating Firmware on Shared SAS Storage (MSA 2040 SAS or P2000 G3 SAS MSA Controller Enclosures and Its Cascaded MSA 2040, P2000, MSA2000, and D2700 Drive Enclosures)
67
Updating Firmware on Zoned SAS Storage (MDS600, D6000, and D2600/D2700 Drive Enclosures)
68
Troubleshooting
69
Gathering Troubleshooting Information
69
Troubleshooting the HP 6Gb SAS BL Switch
69
Troubleshooting MDS600 and D6000 Storage Enclosures
69
Troubleshooting D2600/D2700 Storage Enclosures
70
9 Deployment Examples
71
Introduction
71
Device SAS Port Information
73
HP 6Gb SAS BL Switch Port Information
73
MSA 2040 SAS or P2000 G3 SAS MSA Controller Enclosure Port Information
73
MSA 2040 SAS or P2000 Drive Enclosure Port Information
74
MDS600 and D6000Disk Enclosure Port Information
75
D2600/D2700 Disk Enclosure Port Information
76
External SAS Device, Controller, Drive, and Cabling Support Matrices
77
External SAS Device, Controller, and Drive Support Matrix
77
Cabling Method Support Matrix
77
Illustrated Configuration Examples
79
P2000 G3 SAS MSA Single-Controller, Single-Domain, Standard Cabling
80
P2000 G3 SAS MSA Dual-Controller, Single-Domain Optimal Cabling
81
P2000 G3 SAS MSA Dual-Controller, Dual-Domain, Standard Cabling
82
P2000 G3 SAS MSA Dual-Controller, Dual-Domain, Optimal Cabling
83
P2000 G3 SAS MSA with Cascaded Drive Enclosures
84
MDS600 and D6000 Single Domain, Standard Cabling
85
MDS600 and D6000 Single Domain, High-Performance Cabling
86
MDS600 and D6000 Single Domain, High-Performance Cabling, Max Performance
87
MDS600 and D6000 Dual Domain, Standard Cabling
89
MDS600 and D6000 Dual Domain, High-Performance Cabling
90
MDS600 and D6000 to Two C-Class Enclosures
91
D2600/D2700 Single Domain, Standard Cabling
92
D2600/D2700 Dual Domain, Standard Cabling
93
P2000 G3 SAS MSA and D2700 to the same C-Class Enclosure
94
P2000 G3 SAS MSA and MDS600 or D6000 to the same C-Class Enclosure
95
Tape Library Standard Cabling
96
10 Support and Other Resources
97
Contacting HP
97
HP Websites
97
Typographic Conventions
98
Rack Stability
98
Customer Self Repair
98
HP Insight Remote Support Software
99
1 HP Product Documentation Survey
100
A Device Worksheets
101
Solution Summary Worksheet
101
Server and P71 1M, P712M, and P721M/P731M Controller Worksheet
102
HP 6Gb SAS BL Switch Worksheet
103
HP MSA 2040 SAS or P2000 G3 SAS MSA Controller Enclosure Worksheet
104
HP MSA 2040 or P2000 Drive Enclosure Worksheets
105
MDS600 and D6000 Storage Enclosure Worksheet
106
HP D2600/D2700 Storage Enclosure Worksheet
107
Tape and Autoloader Worksheet
108
Index
109
Advertisement
HP StorageWorks D2700 Deployment Manual (74 pages)
HP BladeSystem Deployment Guide for Solutions with 6Gb SAS Switches and External SAS Storage
Brand:
HP
| Category:
Storage
| Size: 2.36 MB
Table of Contents
Table of Contents
3
1 Introduction
6
Topics Discussed in this Guide
6
Devices Referred to in this Guide
7
Documents Referred to in this Guide
7
How to Obtain Detailed Information
8
Information Available in Device Websites
8
Information Available Tasks in the Bladesystem Technical Resources Website
8
Helpful HP Websites
9
Getting Started
9
2 Device Information
10
HP Bladesystem C-Class Enclosures
10
HP Bladesystem C3000 Enclosure
11
For more Information
11
HP Bladesystem C7000 Enclosure
12
For more Information
12
Important Tips
12
HP Bladesystem C-Class Server Blades
13
Proliant Server Blades
13
For more Information
13
Important Tips
14
HP Smart Array P71 1M/P712M SAS Controller
15
For more Information
15
Important Tips
16
HP 6Gb SAS BL Switch
17
For more Information
17
Important Tips
18
HP P2000 G3 SAS MSA Array
19
For more Information
20
Important Tips
21
HP MSL2024, MSL4048, and MSL8096 Tape Libraries and 1/8 G2 Tape Autoloader
23
For more Information
23
Important Tips
23
Rack and Power
25
For more Information
25
3 Software Information
26
HP Onboard Administrator
27
HP 6G Virtual SAS Manager
30
P2000 G3 SAS MSA Array System Storage Management Utility
31
P2000 G3 MSA Array System Command Line Interface
32
HP Systems Insight Manager
33
MSL Tape Libraries and 1/8 G2 Tape Autoloader Remote Management Interface
34
HP MSL Tape Libraries and 1/8 G2 Tape Autoloader Operator Control Panel
35
4 High Availability / Dual Domain Information
36
5 Device Relationships and Mapping Information
37
6 Zoning Information
38
Types of Zone Groups
38
Key Zoning Configuration Steps
38
7 Installation Best Practices and Procedures
39
Key Installation Steps
40
Installation Notes and Best Practices
41
Installation Steps
42
8 Maintenance and Troubleshooting
46
Updating Firmware on Solution Devices
46
Updating Firmware on Bladesystem Components and Devices
46
Updating Firmware on HP 6Gb SAS BL Switches
47
Updating HP 6Gb SAS BL Switch Firmware in Single-Domain Deployments
47
Updating HP 6Gb SAS BL Switch Firmware in Dual-Domain Deployments
49
Updating Firmware on P2000 G3 SAS MSA Controller and Drive Enclosures
50
Troubleshooting
51
Gathering Troubleshooting Information
51
Troubleshooting the HP 6Gb SAS BL Switch
51
9 Deployment Examples
52
Introduction
52
Device SAS Port Information
54
HP 6Gb SAS BL Switch Port Information
54
P2000 G3 SAS MSA Array Controller Enclosure Port Information
54
P2000 Drive Enclosure Port Information
55
D2700 Disk Enclosure Port Information
55
Illustrated Configuration Examples
56
Shared Storage-P2000 G3 SAS MSA Single-Controller, Single-Domain, Standard Cabling
57
Shared Storage-P2000 G3 SAS MSA Dual-Controller, Single-Domain Optimal Cabling
58
Shared Storage-P2000 G3 SAS MSA Dual-Controller, Dual-Domain, Standard Cabling
59
Shared Storage-P2000 G3 SAS MSA Dual-Controller, Dual-Domain, Optimal Cabling
60
Shared Storage-P2000 G3 SAS MSA with Cascaded Drive Enclosures
61
Tape Library-Basic Cabling
62
10 Support and Other Resources
63
Contacting HP
63
HP Websites
63
Typographic Conventions
64
Rack Stability
64
Customer Self Repair
64
HP Insight Remote Support Software
65
HP Product Documentation Survey
65
A Device Worksheets
66
Solution Summary Worksheet
66
Server and P71 1M/P712M Controller Worksheet
67
HP 3Gb SAS BL Switch Worksheet
68
HP P2000 G3 SAS MSA Array Controller Enclosure Worksheet
69
HP P2000 Drive Enclosure Worksheets
70
HP D2700 Storage Enclosure Worksheet
71
Tape and Autoloader Worksheet
72
Index
73
HP StorageWorks D2700 Specifications (25 pages)
D2000 Series disk enclosures
Brand:
HP
| Category:
Enclosure
| Size: 1.81 MB
Advertisement
Related Products
HP D2D4004fc
HP D2D4009i
HP D2D
HP D2220sb
HP StoreOnce D2D4312
HP StoreOnce D2D4106
HP HP D2D2502
HP StorageWorks D2D4009
HP StorageWorks D2D2502 G2
HP StorageWorks D2D2504 G2
HP Categories
Desktop
Laptop
Server
Monitor
Switch
More HP Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL