Intel S1200BTS Specification page 133

Product specification
Hide thumbs Also See for S1200BTS:
Table of Contents

Advertisement

Intel® Server Board S1200BT TPS
T: Threshold value
Rearm Sensors
The rearm is a request for the event status for a sensor to be rechecked and updated
upon a transition between good and bad states. Rearming the sensors can be done
manually or automatically. This column indicates the type supported by the sensor. The
following abbreviations are used in the comment column to describe a sensor:
A: Auto-rearm
M: Manual rearm
I: Rearm by init agent
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the
count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis).
Criticality
Criticality is a classification of the severity and nature of the condition. It also controls
the behavior of the front panel status LED.
Standby
Some sensors operate on standby power. These sensors may be accessed and/or
generate events when the main (system) power is off, but AC power is present.
Revision 1.0
Intel order number G13326-003
Appendix B: Integrated BMC Sensor Tables