Intel SDS2 Specification (145 pages)
Product Specification
Brand:
Intel
| Category:
Server Board
| Size: 0.85 MB
Table of Contents
Revision History
2
Table of Contents
4
Introduction
15
Figure 1. SDS2 Server Board Block Diagram
15
Architecture
16
Processor and Chipset
18
Processors
18
Table 1. SDS2 Intel® Pentium® III Processor Support Matrix
18
Processor Voltage Regulator Module (VRM)
20
Memory Subsystem
20
Memory Configuration
20
Figure 2. SDS2 Memory Bank Layout
21
Table 2. Memory DIMM Pairs
21
C Bus
22
Chipset
22
Table 3. I 2 C Addresses for DIMM Slots
22
CNB20HE-SL Champion North Bridge
23
CIOB20 Champion I/O Bridge
24
CSB5 South Bridge
24
I/O Subsystem
25
PCI Subsystem
25
32-Bit, 33-Mhz PCI Subsystem
25
Table 4. PCI Bus Segment Characteristics
25
64-Bit, 66-Mhz PCI Subsystem
26
Table 5. P32-A Configuration Ids
26
Table 6. P32-A Arbitration Connections
26
Table 7. P64-B Arbitration Connections
27
Table 8. P64-B Arbitration Connections
27
Ultra160 SCSI
28
Video Controller
28
Video Modes
28
Network Interface Controller (NIC)
29
Table 9. Video Modes
29
NIC Connector and Status Leds
30
CSB5 South Bridge (PCI-To-LPC Bridge, IDE, USB)
30
PCI Bus Interface
30
PCI Bus Master IDE Interface
30
USB Interface
31
Compatibility Interrupt Control
31
Apic
31
Power Management
31
General Purpose Input and Output Pins
31
Table 10. CSB5 GPIO Usage Table
31
Chipset Support Components
32
Super I/O
32
Table 11. Super I/O GPIO Usage Table
32
BIOS Flash
34
Interrupt Routing
34
Legacy Interrupt Routing
34
Table 12. PCI Interrupt Routing/Sharing
34
Table 13. Interrupt Definitions
34
APIC Interrupt Routing
35
Serialized IRQ Support
35
IRQ Scan for PCIIRQ
35
Figure 3. SDS2 Interrupt Routing Diagram (CSB5 Internal)
36
Figure 4. SDS2 Interrupt Routing Diagram
37
Figure 5. SDS2 PCI Interrupt Mapping Diagram
38
Server Management
39
Figure 6. SDS2 Sahalee BMC Block Diagram (View as Reference Only)
40
Sahalee Baseboard Management Controller
41
Table 14. ADM1026 Input Definition
41
Table 15. Temperature Sensors
42
Table 16. Sahalee Input Definition
42
Fault Resilient Booting
43
Figure 7. SDS2 Locations of ADM1026 and Sahalee
43
System Reset Control
44
Power-Up Reset
44
Hard Reset
44
Soft Reset
44
Intelligent Platform Management Buses
44
Table 17. IPMB Bus Devices
45
Table 18. Private I C Bus 1 Devices
45
Table 19. Private I C Bus 2 Devices
45
Table 20. Private I C Bus 3 Devices
45
Error Reporting
46
Error Sources and Types
46
PCI Bus Errors
46
Intel® Pentium® III Processor Bus Errors
46
Table 21. Private I C Bus 4 Devices
46
Memory Bus Errors
47
ID Led
47
Acpi
47
AC Link Mode
47
Bios
49
System BIOS
49
BIOS Error Handling
50
Error Sources and Types
50
Handling and Logging System Errors
50
Table 22. BIOS Generated SEL Errors
51
SMI Handler
52
Table 23: Event Request Message Event Data Field Contents
52
Firmware (BMC)
53
Table 24 Platform SEL Log Sensors for SDS2
53
Error Messages and Error Codes
59
Table 25. Event Request Message Event Data Field Contents
59
Table 26. Port-80H Code Definition
59
Table 27. Standard BIOS POST Codes
60
Table 28. Recovery BIOS POST Codes
63
Table 29. POST Error Messages and Codes
64
Table 30. BMC Beep Codes
65
Setup Utility
66
Configuration Utilities Overview
66
Setup Utility Operation
66
Table 31. Setup Utility Screen
66
Table 32. Main Menu Selections
69
Table 33. Primary Master and Slave IDE Submenu Selections
70
Table 34. Processor Settings Submenu Selections
71
Table 35. Advanced Menu Selections
72
Table 36. Memory Configuration Menu Selections
72
Table 37. PCI Configuration Menu Selections
73
Table 38. On-Board SCSI and LAN Submenu Selections
73
Table 39. On-Board VGA Submenu Selections
73
Table 40. PCI Slot Submenu Selections
73
Table 41. I/O Device/Peripheral Configuration Submenu Selections
75
Table 42. Advanced Chipset Controller Submenu Selections
76
Table 43. PCI Device Submenu Selections
76
Table 44. Security Menu Selections
76
Table 45. Server Menu Selections
77
Table 46. System Management Submenu Selections
78
Table 47. Console Redirection Submenu Selections
79
Table 48. Boot Device Priority Selections
79
Table 49. Hard Drive Selections
80
Table 50. Removable Drive Selections
80
Table 51. Exit Menu Selections
80
CMOS Memory Definition
81
Clearing CMOS
81
Flash Update Utility
81
Loading the System BIOS
81
User Binary Area
82
Language Area
82
OEM Logo Screen
82
Recovery Mode
82
Clock/Voltage Generation and Distribution
84
Clock
84
Figure 8. SDS2 Server Board Clock Generation/Distribution Diagram
85
Voltage
86
Figure 9. SDS2 Server Board Voltage Generation/Distribution Diagram
87
Connections
88
Power Distribution Board Connector
88
Table 52. 24-Pin Main Power Connector Pin-Out
88
Table 53. 8-Pin +12 V Power Connector Pin-Out
88
Table 54. Aux Signal Connector Pin-Out
88
Memory Module Connector
89
Table 55. DIMM Connector Pin-Out
89
System Management Headers
90
ICMB Connector
90
OEM IPMB Connector
90
SCSI HSBP (IPMB) Connector
90
Table 56. ICMB Connector Pin-Out
90
Table 57. IPMB Connector Pin-Out
90
Table 58. HSBP-A Connector Pin-Out
90
Front Panel Header
91
Table 59. HSBP-B Connector Pin-Out
91
Table 60. Front Panel 34-Pin Header Pin-Out
91
PCI Slot Connector
92
Table 61. 32-Bit 5 V PCI Slot Pin-Out
92
Table 62: 64-Bit 3.3V PCI Slot Pin-Out
92
I/O Connectors
94
VGA Connector
94
SCSI Connector
94
Table 63. VGA Connector Pin-Out
94
Table 64. 68-Pin SCSI Connector Pin-Out
94
NIC Connectors
95
Table 65. RJ-45 Connector Pin-Out
95
IDE Connector
96
Universal Serial Bus (USB) Connectors
96
Table 66. IDE 40-Pin Connector Pin-Out
96
Table 67. Stacked Three-Port USB Connector Pin-Out
96
Floppy Connector
97
Table 68. 10-Pin USB Connection Header (2 X 5) Pin-Out
97
Serial Port Connector
98
Table 69. 34-Pin Floppy Connector Pin-Out
98
Table 70. DB9 Serial Port Pin-Out
98
Table 71. 10-Pin Header Serial Port Pin-Out
98
Parallel Port
99
Keyboard and Mouse Connector
99
Table 72. DB25 Parallel Port Pin-Out
99
Table 73. Keyboard and Mouse PS/2 Connector Pin-Out
99
Miscellaneous Headers
100
Fan Headers
100
Chassis Intrusion
100
External SCSI Activity LED Input Signal Connector
100
Table 74. Fan Header Pin-Out
100
Table 75. Chassis Intrusion Header Pin-Out
100
Rear I/O Panel
101
Connector Manufacturers and Part Numbers
101
Figure 10. SDS2 Server Board Rear I/O Panel
101
Table 76. External Drive Activity Header Pin-Out
101
Table 77. Server Board Connector Manufacturer Part Numbers
101
Figure 11. SDS2 Configuration Jumpers
103
Figure 12. SDS2 Configuration Jumper Locations
104
Table 78. System Configuration Jumper Options
105
Table 79. CPU Frequency Select Jumper Options
105
Jumpers
106
Performing CMOS Clear, BIOS Recovery, and BMC Force Update
106
Performing CMOS Clear
106
Performing BIOS Recovery Boot
106
Table 80. List of Assembled Jumpers in Production
106
Performing BMC Force Update
107
10. Electrical and Thermal Specifications
108
10.1 Absolute Maximum Ratings
108
10.2 Power Consumption
108
Table 81. Absolute Maximum Ratings
108
10.3 Power Supply Specification
109
Power Timing
109
Table 82. SDS2 Server Board Power Consumption
109
Table 83: SDS2 Power Supply Specification
109
Table 84: Voltage Timing Parameters
109
10.4 Estimateded Server Board MTBF
111
Figure 13. Output Voltage Timing
111
Table 85: Turn On/Off Timing
111
Table 87. Estimated SDS2 Server Board MTBF
111
11. Mechanical Specifications
112
Figure 14. Turn On/Off Timing
112
Figure 15. SDS2 Server Board Mechanical Drawing
112
12. Regulatory and Integration Information
113
12.1 Regulatory Compliance
113
Table 86. Transient Load Requirements
113
Table 88. Safety Regulations
113
Table 89. EMC Regulations
113
12.2 Installation Instructions
114
Ensure EMC
114
Ensure Host Computer and Accessory Module Certifications
115
Prevent Power Supply Overload
115
Place Battery Marking on Computer
115
Use Only for Intended Applications
116
Installation Precautions
116
External ICMB Cable Information
116
Table 90. ICMB External Cable Connectors
116
13. Errata Listing
117
13.1 Summary Errata Table
117
Table 91. Errata Summary
117
13.2 Errata
119
Intel® RAID Controller SRCMR Not yet Supported with Intel® Server Board SDS2
119
Intel® Server Board SDS2 BIOS Update Utility Does Not Allow Updates from a PXE Server or from Network Drives
119
Intel® Server Board SDS2 FRU/SDR Update Fails with Console Redirection Enabled in BIOS Setup
119
First Characters and Arrow Keys Not Echoed with Console Redirection
120
Intel® & ICP Vortex* RAID Controllers will Cause the Intel® Server Board SDS2 to Halt During POST When the BIOS Logo Screen Is Enabled
120
Intel® Server Board SDS2 CD-ROM Issues
121
NIC Driver Set 5.12 V.2.3.15 for Unixware* 7.1.1 Drops DPC LAN Connection
122
NIC Driver Set 5.12 V.5.41.27 for Microsoft* Windows* 2000 Prevents a DPC LAN Connection When the Operating System Is Loaded
122
Extended RAM Step Disable Option in BIOS Setup Has no Effect
123
High Resolution Video Modes Do Not Work Correctly
123
Lower Performance with CAS Latency 2 Memory
124
SDS2 Reboots During POST with 4GB or more of Total System Memory Installed
124
Novell Netware* V. 6.0 Does Not Install on SDS2
125
Adaptec* 2100S RAID Controller Causes System Lockup and Video Blanking
125
SDS2 Build Your Own (BYO) Platform Confidence Test (PCT) V. 1.00 Fails on the First Run
126
SDS2 0B71: System Temperature out of the Range POST Message
126
SDS2 0B75: System Voltage out of the Range POST Message
127
Miscellaneous Numeric Keys Entered During POST Enable PXE Boot
127
SDS2 Board Level Operating Temperature and Power Supply Voltage Tolerance Modification
128
Recommendation for SDS2 Rubber Bumper Installation
128
Keyboard and Mouse Do Not Function under Microsoft* Windows* 2000 When Legacy USB Is Enabled in BIOS Setup
130
Data Miscompares When Using Seagate* ATA III Model ST310215A Hard Drives
131
Boot to Service Partition Via Modem Fails
131
Potential Mylex Acceleraid 352 Adaptor Card Mechanical Interference at PCI Slot
131
Secondary IDE References Added to Documentation for FAB 5
131
Bootable CD will Not Boot if Inserted During OPTION ROM Scan
132
Swapping Bootable for Non-Bootable CDROM During POST Causes Hang at Boot
132
OB P100 Nics Do Not Show at POST but Attempt PXE Boot and Appear in Boot Menu122
133
Dodson: Adaptec 39160 in Slots 5 & 6 Causes Expansion ROM Error
133
Can Not Change BIOS SETUP IDE Options Using <Enter> Key
134
Minimum Wait Time between Power off and Power on Via Front Panel Power Button Is One Second
134
Unable to Boot Netware 6.0 (NW6) from CD ROM with Adaptec Adaptor 2100S in Slot
134
COM* 3C980C-TX NIC Causes Microsoft* Windows* 2000 Blue Screen When Greater than 4GB of System Memory Is Installed
135
Peer-To-Peer PCI Transactions Are Not Supported between the CIOB-Controlled 64-Bit PCI Bus and the Legacy 32-Bit PCI Bus Controlled by the HE-SL North Bridge
136
SDS2 PCI Slot Current Levels Supported by the 5V Rail
136
OB P100 Nics Do Not Show at POST but Attempt PXE Boot and Appear in Boot Menu125
136
Glossary
138
Reference Documents
140
Index
141
Advertisement
Intel SDS2 Product Manual (100 pages)
Brand:
Intel
| Category:
Server Board
| Size: 0.36 MB
Table of Contents
Table of Contents
3
Tables
7
Description
7
Server Board Features
7
Back Panel Connectors
8
Server Board Connector and Component Locations
9
Processor
10
Memory
10
Figures
8
Add-In Board Slots
11
SCSI Controller
12
Video
12
Video Modes
12
IDE Controller
13
USB Interface
13
Network Controller
14
Network Teaming Features
14
Acpi
16
Keyboard and Mouse
16
Security
16
Security with Mechanical Locks and Monitoring
16
Software Locks
17
Software Security Features
18
Server Board Installation
21
Tools and Supplies Needed
21
Before You Begin
21
Emissions Disclaimer
21
Safety Cautions
21
Safety and Regulatory Compliance
22
Minimum Hardware Requirements
22
Installation Notes
23
Installation Procedures
23
Installing the I/O Gasket and Shield
23
Attaching the Gasket to the I/O Shield
24
Attaching the Label to the I/O Shield
24
Installing the I/O Shield
25
Installing the Processor(S)
26
Lifting the Locking Bar
26
Inserting the Processor
27
Attaching the Heat Sink and Retention Clip
28
Locking the Heat Sink Retention Clip
29
Attaching the Heat Sink Fan
29
Installing Memory
30
Installing a Terminator
30
Installing Memory
31
Configuring Chassis Standoffs
32
Installing the Server Board
33
Making Connections to the Server Board
34
Cable Routing
35
Routing Cables
35
Installing the COM2 Cable
36
Finishing up
37
Getting Started with Intel Server Management (Optional)
38
Upgrading
41
Tools and Supplies Needed
41
Cautions
41
Memory
42
Processors
43
Adding or Replacing a Processor
44
Raise the Locking Bar
44
Insert the Processor
45
Lock the Heat Sink Retention Clip
46
Attach the Fan
46
Removing a Processor
47
Installing or Removing a Terminator
47
Installing a Terminator
47
Replacing the Back up Battery
48
Replacing the Back up Battery
49
Configuration Software and Utilities
51
Hot Keys
51
Configuration Utilities
51
Power-On Self-Test (POST)
52
Using BIOS Setup
53
Record Your Setup Settings
53
If You Cannot Access Setup
53
Starting Setup
53
Setup Menus
54
Main Menu
54
Primary Master/Slave Submenu
55
Processor Settings Submenu
55
Advanced Menu
56
Pci Configuration Submenu
57
Security Menu
59
Server Menu
60
Boot Menu
61
Exit Menu
62
Using the System Setup Utility
63
What You Need to Do
63
Running the SSU from the CD
63
Running the SSU Remotely Via an Emergency Management Card
64
Starting the SSU
64
Customizing the SSU
65
Launching a Task
65
SEL Manager Add-In
66
SDR Manager Add-In
67
FRU Manager Add-In
68
Exiting the SSU
68
FRUSDR Load Utility
69
When to Run the FRUSDR Load Utility
69
What You Need to Do
69
How You Use the FRUSDR Load Utility
69
Command Line Format
70
Upgrading the BIOS
73
Preparing for the Upgrade
73
Upgrading the BIOS
74
Recovering the BIOS
75
Changing the BIOS Language
75
Using the Firmware Update Utility
76
Making a BMC Firmware Update Diskette
76
Updating the BMC Firmware
76
Recovering the BMC Firmware
77
Updating the FRU/SDR Files
77
Making a FRU/SDR File Update Diskette
77
Using the Adaptec SCSI Utility
78
Running the SCSI Utility
78
Solving Problems
79
Resetting the System
79
Initial System Startup
79
Checklist
79
Running New Application Software
80
Checklist
80
After the System Has Been Running Correctly
80
More Problem Solving Procedures
81
Preparing the System for Diagnostic Testing
81
Monitoring POST
81
Verifying Proper Operation of Key System Lights
81
Confirming Loading of the Operating System
81
Specific Problems and Corrective Actions
82
Power Light Does Not Light
82
No Characters Appear on Screen
82
Characters Are Distorted or Incorrect
83
System Cooling Fans Do Not Rotate Properly
83
Diskette Drive Activity Light Does Not Light
84
Hard Disk Drive Activity Light Does Not Light
84
CD-ROM Drive Activity Light Does Not Light
84
Cannot Connect to a Server
84
Problems with Network
85
PCI Installation Tips
85
Problems with Application Software
86
Bootable CD-ROM Is Not Detected
86
Getting Help
87
Technical Reference
89
Server Board Jumpers
89
Configuration Jumper (CN46)
90
Regulatory and Integration Information
91
Product Regulatory Compliance
91
Product Safety Compliance
91
Product EMC Compliance
91
Product Regulatory Compliance Markings
92
Electromagnetic Compatibility Notices
92
Fcc (Usa)
92
Industry Canada (Ices-003)
93
Europe (CE Declaration of Conformity)
93
Equipment Log Worksheet
95
Equipment Log
95
Index
97
Intel SDS2 Parts List (8 pages)
Server Board and Server Chassis
Brand:
Intel
| Category:
Network Hardware
| Size: 0.11 MB
Advertisement
Intel SDS2 Quick Start Manual (2 pages)
Quick Start Guide
Brand:
Intel
| Category:
Server Board
| Size: 0.89 MB
Advertisement
Related Products
Intel S3210SH
Intel S5500BCR
Intel S5500WB12V
Intel S875WP1LX
Intel SE7210TP1
Intel SE7221BA1
Intel SE7505VB2
Intel Server Board S5500HV
Intel SE7520JR2SCSID1 - Server Board SE7520JR2
Intel SE7501WV2SCSI
Intel Categories
Motherboard
Computer Hardware
Server
Server Board
Desktop
More Intel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL