a. Make sure that the thermal material is still on the bottom of the heat sink; then, align the heat sink
so that the arrows on the label point toward the DIMMs and place the heat sink on top of the
microprocessor, thermal material side down.
b. Align the screw holes 1 on the heat sink with the holes on the system board 3 Following is an
illustration of the heat sink orientation.
Heatsink
Orientation
DIMMs
DIMMs
c. Tighten the screws with a screwdriver, alternating among the screws until they are tight. If
possible, each screw should be rotated two full rotations at a time. Repeat until the screws are
tight. Do not overtighten the screws by using excessive force.
6. Go to "Completing the installation" on page 47.

Thermal grease

The thermal grease must be replaced whenever the heat sink has been removed from the top of the
microprocessor and is going to be reused or when debris is found in the grease.
When you are installing the heat sink on the same microprocessor that is was removed from, make sure
that the following requirements are met:
v The thermal grease on the heat sink and microprocessor is not contaminated.
v Additional thermal grease is not added to the existing thermal grease on the heat sink and
microprocessor.
Note:
1. Read the safety information at "Safety" on page vii.
2. Read "Installation guidelines" on page 25.