v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs)
and which components are field replaceable units (FRUs).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
v Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints,
tips, or new device drivers.
Error code
Description
0058007
DIMM population is unsupported.
0058008
DIMM failed memory test.
00580A4
Memory population changed.
0068002
CMOS battery cleared.
2011001
PCI-X PERR
Action
1. Make sure the installed DIMMs follow the
population rules and sequence described in
"Installing a memory module" on page 36.
2. Reseat the DIMMs, and then restart the server.
3. Remove the lowest-numbered DIMM pair of
those that are identified and replace it with an
identical pair of known good DIMMs, then restart
the server.
4. Return the removed DIMMs, one pair at a time,
to their original connectors, restarting the server
after each pair, until a pair fails. Replace the
DIMMs in the failed pair with identical known
good DIMMs, restarting the server after each
DIMM is installed. Replace the failed DIMM.
Repeat this step until you have tested all removed
DIMMs.
5. (Trained service technician only) Replace the
system board.
1. Reseat the DIMMs, and then restart the server.
2. Replace the following components one at a time,
in the order shown, then restart the server after
each:
a. DIMM
b. (Trained service technician only) System board
Information only. Memory has been added, moved,
or changed.
1. Reseat the battery.
2. Clear the CMOS memory (see Table 4 on page 20).
3. Replace the following components one at a time,
in the following order, restarting the server after
each one:
a. Battery
b. (Trained service technician only) System board
1. Check the riser-card LEDs.
2. Reseat all affected adapters and riser cards.
3. Update the PCI adapter firmware.
4. Remove the adapter from the riser card.
5. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Riser card
b. (Trained service technician only) System board
Chapter 8. Solving problems