Deploying a Collector
To add a Collector:
1 In the main ESM display, locate the Collector Manager to which the new Collector will be
associated.
2 Right-click the Collector Manager and select the Add Collector menu item.
3 Follow the prompts in the Add Collector wizard.
4 Click Finish.
NOTE: Collector Script enables the ESM panel to prompt you for parameter values as well as
enable ESM to automatically select supported connection methods that work well with the Collector
Script.
Deploying a Connector
To add a Connector:
1 In the main ESM display, locate the Collector to which the new Connector will be associated.
2 Right-click the Collector and select the Add Connector menu item.
3 Follow the prompts in the Add Connector wizard.
4 Click Finish.
Deploying an Event Source
To add an Event Source:
1 In the main ESM display, locate the Connector to which the new Event Source will be
associated.
2 Right-click the Connector and select the Add Event Source menu item.
3 Follow the prompts in the Add Event Source wizard.
4 Click Finish.
Deploying Event Source Servers
Certain Event Source Connectors (such as the Syslog Connector) require a process to collect data
from the actual data source. These processes are called "Event Source Servers". They collect data
from the data source and then "serve" it to the Event Source Connector. Event Source Servers must
be added and associated to any Event Source Connectors that require a server.
To add an Event Source Server:
1 In the Live View, right-click the Collector Manager and select Add Event Source Server. Select
Connector window displays.