MC-12 Serial Communications Protocol
Record Active:
Data Type:
TRUE:
FALSE:
Zone 2 Balance:
Data Type:
Max:
Min:

7.3.47 MC-12 Set System Volume (MC-12)

This command is a request to the MC-12 to set the system volume with the value in this packet.
7.3.47.1 Command Packet Description
Application Header:
Command MC_CMD_SET_SYS_VOLUME
Data Count 1
Application Data:
Data[0]
7.3.47.2 Data Description
Value:
Data Type:
Max:
Min:
7.3.47.3 MC-12 Response
The MC-12 will assign the value from the packet to the system volume.
7.3.47.4 Data Validation
If a value is passed that exceeds the maximum value of that parameter the MC-12 will ignore the command
and transmit a DC_NAK command with an error code DC_INVALID_DATA.

7.3.48 MC-12 Set Main Balance (MC-12)

Commands MC-12 to set the system balance to the value in this packet.
7.3.48.1 Command Packet Description
Application Header:
Command
Data Count 1
Application Data:
Data[0]
© 2004 Harman Specialty Group All rights reserved.
Boolean.
Record Zone Output is active
Record Zone Output is not Active.
Signed 8 bit integer (2's compliment)
16 (0x10) (Full Right)
-16 (0xF0) (Full Left)
Value
Signed 8 bit integer (2's compliment)
+12 (0x0C) (12 dB)
-80 (0xB0) (-80 dB)
DC_CMD_SET_SYS_BALANCE
Value
Printed on: 07/19/04
0x40
0x01
nn
0x41
0x01
nn
48 of 102