1.5.2 Send MC-1 IR Command Example

SOP
DLL DC
CMD
F1
04
14
This example shows how to transmit the MC-1 IR command for "Volume Up". The bytes are transmitted
from left to right and they are defined as:
Byte 0: Start of Packet(F1 hex)
Byte 1: Data Link Layer(DLL) Data Count(DC); for an IR command this would be 4 bytes to
follow
Byte 2: The Application Layer Command, in this case it is 14 hex indicating this is an IR
command packet.
Byte 3: The Application Layer Data Count(DC); for this packet it is 1 data byte to follow.
Byte 4: The Application Command Data: This IR Command Packet is transmitting Key Code
"Volume Up"(17 hex). To transmit other IR Key Codes the user would replace this byte
with other IR key codes as found in
Byte 5: End of Packet (F2 hex)
© 2004 Harman Specialty Group All rights reserved.
AppDC DATA0
EOP
IR Key
Code
01
17
F2
Appendix C MC-12
Printed on: 07/19/04
IR-Codes.