Burn In Loop (12) - Lexicon MPX 110 Service Manual

24 bit dual channel processor
Hide thumbs Also See for MPX 110:
Table of Contents

Advertisement

Edit
Bypass
O
O
MSB
Pressing the STORE button will execute the test.
When the test is executed the remaining buttons, encoders, ADC Pots, and footswitches (2) are inactive,
and all Front Panel LED's will go off.
If the test passed, the L & R Level (green) LED's will light.
If the test failed, the L & R Clip (red) LED's will light.
To run the test again, press the STORE button.
To run the test continuously, press the TAP button.
To stop the test from running continuously, press the STORE button.

BURN IN LOOP (12)

The Burn In Loop will continuously run the following diagnostics:
Test
Number
1
2
3
4
5
11
When selected, the Binary LED's will read the following:
Edit
Bypass
O
O
MSB
Pressing the STORE button will execute the test.
When the test is executed the remaining buttons, encoders, ADC Pots and footswitches (2) are inactive.
During the execution of the Diagnostics in the Burn In loop, the appropriate test code will be displayed on
the binary LED's. This code will be sent to the LED's before each test is executed. By displaying a test/error
code on the LED's before the test is activated, it will be easier to determine which test failed if the unit
hangs or crashes during the Burn In Loop.
If a test failed, the Burn In Loop will stop and the Binary LED's will display which test failed along with the L
& R Clip (red) LED's lit.
There are three options available when a test has failed during the Burn In Loop:
1. Press the BYPASS button to continue the Burn In Loop.
2. Press the TAP button to run the test continuously.
3. Press the STORE button to exit the Burn In Loop.
Store
Tap
l
O
LSB
Test Name
ROM Checksum
SRAM Test
Lexichip3 WCS
Lexichip3 Interrupt Timer
Lexichip3 Audio Data File
Lexichip3 External DRAM
Store
Tap
O
l
LSB
Lexicon
Binary
LED's
0 0 0 1
0 0 1 0
0 0 1 1
0 1 0 0
0 1 0 1
1 0 1 1
5-15