Mc-12 Set Parameter Value By Id, No Run (Mc-12); Mc-12 Get Unit Configuration (Mc-12) - Lexicon MC-12 V4.0 - SERIAL COMMUNICATIONS PROTOCOL DEFINITION REV 1-6 Manual

Serial communications protocol definition software version 4.0
Table of Contents

Advertisement

Lexicon
MC-12 Serial Communications Protocol
NAK packet with a DC_INVALID_INPUT error code. The MC-12 will transmit a NAK packet with a
DC_ERR_READ_ONLY error code for read only parameters.

7.3.38 MC-12 Set Parameter Value by Id, No Run (MC-12)

MC-12 Set Parameter by Id command sets the parameter value equal to the value sent in the command
packet and does not run the appropriate functional changes associated with changing the given parameter.
7.3.38.1 Command Packet Description
Application Header:
Command
MC_CMD_SET_SYS_PARAM_VALUE_BY_ID_NO_RUN 0x37
Data Count 24
Application Data:
Data[0]
ParamId(LSB)
Data[1]
ParamId(MSB)
Data[2]
ParamType
Data[3-23]
Value[0 -20]
7.3.38.2 Data Description
Same as
Paragraph 7.3.37.2

7.3.39 MC-12 Get Unit Configuration (MC-12)

Request to MC-12 for its current unit configuration. MC-12 will respond with "Unit Configuration Packet".
The HOST should use this information to determine if any information saved by the HOST is current.
7.3.39.1 Command Packet Description
Application Header:
Command
Data Count
Application Data:
© 2004 Harman Specialty Group All rights reserved.
MC_CMD_GET_CONFIG
0
N/A
Printed on: 07/19/04
0x18
nn
nn
nn
nn nn
nn...
0x38
0x00
39 of 102