MC-12 Serial Communications Protocol

7.3.6 Get Zone 2 Status (MC-12, MC-1)

This command is a request to MC-12 for current Zone 2 Status. MC-12 will respond with "Zone2 Status
Packet".
This command has been maintained for backward compatibility with MC-1. In order to maintain backward
compatibility, the MC-12 Parameters have been mapped to the MC-1 parameters as described in each Data
Description. MC-12 users should be using the command described in
7.3.6.1 Command Packet Description
Application Header:
Command DC_CMD_GET_ZONE2_STATUS 0x17
Data Count 0
Application Data:
7.3.6.2 Zone2 Status Response Packet
Application Header:
Command DC_RESP_ZONE2_STATUS
Data Count 5
Application Data:
Data[0]
Data[1]
Data[2]
Data[3]
Data[4]
7.3.6.3 Data Description
Zone2 Volume:
Data Type:
Maximum Value: 92
Conversion:
Assigned Zone 2 Input:
Indicates the Zone 2 input that is currently assigned for the zone 2 outputs.
Data Type:
Definition/Conversion:
Zone2 Mute Active:
Data Type:
TRUE:
FALSE:
Record Active:
Data Type:
TRUE:
FALSE:
© 2004 Harman Specialty Group All rights reserved.
N/A
Zone2 Volume
Assigned Zone 2 Input
Zone2 Mute Active
Record Active
Zone2 Balance
Unsigned 8 bit integer.
0 = -80 dB
92 = +12 dB
Unsigned 8 bit integer.
Appendix F MC-12 Input Ids
Boolean.
Zone2 Outputs are active.
Zone 2 Outputs are not active.
Boolean.
Record Zone Output is active
Record Zone Output is not Active.
Printed on: 07/19/04
7.3.46
(MC12_Get_Zone_2_Status).
0x00
0x82
0x05
nn
nn
nn
nn
nn
22 of 102