Security Menu - Lexmark 19Z0200 - X 860de 4 B/W Laser User Manual

User's guide
Hide thumbs Also See for 19Z0200 - X 860de 4 B/W Laser:
Table of Contents

Advertisement

Understanding printer menus

Security menu

Miscellaneous menu
Menu item
Panel Logins
Login failures
Failure time frame
Lockout time
Panel Login Timeout
Remote Login Timeout
Remote Logins
Login failures
Failure time frame
Lockout time
Login timeout
Confidential Print menu
Menu item
Max Invalid PIN
Off
2–10
Description
Limits the number and time frames of failed login attempts from the printer control
panel before all users are locked out
Notes:
"Login failures" specifies the number of failed login attempts before users are
locked out. Settings range from 1–50. 3 attempts is the factory default setting.
"Failure time frame" specifies the time frame during which failed login
attempts can be made before users are locked out. Settings range from 1–60
minutes. 5 minutes is the factory default setting.
"Lockout time" specifies how long users are locked out after exceeding the
login failures limit. Settings range from 0–60 minutes. 5 minutes is the factory
default setting. 0 indicates the printer does not impose a lockout time.
"Panel Login Timeout" specifies how long the printer remains idle on the
Home screen before automatically logging the user off. Settings range from 1–
900 seconds. 300 seconds is the factory default setting.
Limits the number and time frames of failed login attempts from a computer before
all remote users are locked out
Notes:
"Login failures" specifies the number of failed login attempts before users are
locked out. Settings range from 1–50. 3 attempts is the factory default setting.
"Failure time frame" specifies the time frame during which failed login
attempts can be made before users are locked out. Settings range from 1–60
minutes. 5 minutes is the factory default setting.
"Lockout time" specifies how long a user is locked out after exceeding the
login failures limit. Settings range from 0–60 minutes. 5 minutes is the factory
default setting. 0 indicates the printer does not impose a lockout time.
"Login timeout" specifies how long the remote interface remains idle before
automatically logging the user off. Settings range from 1–900 seconds. 300
seconds is the factory default setting.
Description
Limits the number of times an invalid PIN can be entered
Notes:
Off is the default setting.
This menu item appears only if a printer hard disk is installed.
Once a limit is reached, the jobs for that user name and that PIN are deleted.
153

Advertisement

Table of Contents
loading

This manual is also suitable for:

X860X862X864X860deX864deX862de

Table of Contents