[Ent1.4]
message=Hub %b collision count over %a
event=1,Trap
a=groupTotalCollisions,v
b=groupTotalCollisions,i5
[Ent1.5]
message=Hub %b alignment error count over %a
event=1,Trap
a=groupFAEErrors,v
b=groupFAEErrors,i5
[Ent1.6]
message=Hub %b CRC error count over %a
event=1,Trap
a=groupCRCErrors,v
b=portCRCErrors,i5
[Ent1.7]
message=Port(%b,%c)length < 64 bits count over %a
event=1, Trap
a=portPygmys,v
b=portPygmys,i5
c=portPygmys,i6
[Ent1.8]
message=Port (%b, %c) CRC error count over %a
event=1, Trap
a=portCRCErrors, v
b=portCRCErrors,i5
c=portCRCErrors,i6
From the preceding example, you can view the following data:
• There are 8 specific traps Available for enterprise number 1.
• All traps are active (event=1).
• When a trap is activated, it will trigger a specified event called "Trap" and display the
corresponding message on screen. Supposed trap number 4 is triggered [Ent1.4].
• Trap number 4 contains the group variable TotalCollisions in its variable-bindings, which has 5
numbers.
• Supposed that trap number 4 is triggered and the 5th number in the index of
groupTotalCollisions is 2, and the value of the variable is 20. The Event Manager will display the
following message on screen: Hub 2 collision count over 20.