Table 15. LCD Message Troubleshooting Table
Displayed Message
EXCESS RBN WEAR
Yes
Install New RBN
EXHAUST FAN FLT
Yes
(Cabinet model only)
FIRMWARE ERROR*
No
FM HEADER ERROR*
No
FRAMING ERROR
Yes
GRF CHK ERROR
Yes
PRESS STOP
H00: PCI SLOT ?
No
See User Manual
Can User
Explanation
Correct?
Status message that
displays when ribbon
reaches end of life,
whether the Integrated
Print Management
System is enabled or not.
Sensors cannot detect
current in fan circuit.
Application software tried
to perform an illegal
printer function or
damaged memory
detected on the controller
board.
Frame Header Error.
Application software has
violated header
parameters.
The printed output may
contain random !
(exclamation point)
characters.
Graphic Check Error: in
the CT emulation over a
twinax interface, the
printer received a non-
printable character.
The controller board is
not communicating with a
PCI card. This could
indicate a bad PCI card,
poor connection, or
problem in the PCI bus.
Fault Messages
Solution
Install a new ribbon.
Power off the printer and remove
the paper path (see Maintenance
Manual). Check that the fan cable
connector is connected. Check for
obstruction of vents and fan airway,
and remove any obstructions.
Check for items beneath the printer
blocking cabinet vents. Power back
on the printer. If this message
appears again, contact your
authorized service representative.
Contact your authorized service
1
representative.
Contact your system administrator.
Make a configuation printout. Set
printer serial interface parameters to
match host configuration settings
for Data Protocol, Baud Rate, Data
Bits, Stop Bits, Parity, Data Terminal
Ready, and Request to Send.
Press CLEAR and then ON LINE.
Contact your authorized service
1
representative.
1