Chapter
4
LinePrinter Plus Emulation (With PCL-II)
Printer Select
Disable (default). Ignores the ASCII DC1 and DC3 control codes.
Enable. Disables the printer when a DC1 control code is received, and
enables the printer when a DC3 control code is received.
Character Set
This parameter selects a character set for the Epson emulation, as shown in
the "Epson FX Character Set Menu" on page 165. Note that when OCR-A or
OCR-B is selected as the print language, the Font Attribute Typeface option
under the LinePrinter Plus menu (page 140) is changed to OCR-A or OCR-B,
respectively.
To use one of these sets, choose the desired group heading (such as
European Sets) and press ENTER. Then choose the desired set within that
group (such as Roman 8) and press ENTER. Both the group and the desired
set will be starred to indicate your selection. The UTF-8 selection allows
printing of UTF-8 encoded Unicode ™. Character sets are shown in detail in
the Character Sets Reference Manual .
20 CPI Condensed
Compressed print characters are narrower than the normal character set.
This is helpful for applications where you need to print the maximum amount
of information on a page.
Enable (default). Prints about 60 percent of the width of normal
characters when compressed print is chosen by the host computer. For
example, a 12 CPI Draft font will compress to 20 CPI.
Disable. Does not compress print widths, even if condensed print is
chosen by the host.
Alt. Set 80-9F
Control Code (default). Interprets data in the range of hex 80 through
hex 9F as a control code.
Printable. Prints data in the range of hex 80 through hex 9F.
164