4
Coax/Twinax (CTHI) Emulation
Translation Tbl
Prints out a table of the TN5250 interface's current character set. This
operation is valid only when the TN5250 interface is the current interface.
Active Char Set
Selects which group of character sets (Primary or Secondary) will be active.
Secondary Set (default)
Primary Set
Prt Partial Line
Enable (default). When this option is enabled, it forces the printer to print
if a partial line is in the printer (i.e. line not ending with a LF).
Disable. When disabled, the last partial line of data will not be printed.
PTX Transparent
Lead-in Chars
You can enable additional printer features which are not accessible through
standard TN5250 emulations. To access these features, send text commands
in the data stream. The commands must have a start and end code. Four sets
are available:
Set 1. start code: <% (default)
Set 2. start code:
Set 3. start code: _%
User Defined.
Usr Defined HTRN
This option is used to set user defined lead-in characters. The range is ASCII
character. This option allows users to define ther own lead-in characters for
the Printronix Specific commands. Select a hex value for the following codes
for the User Defined option:
Start Code 1 5F (default)
Start Code 2 5F
Stop Code 5B
Alt. Set 80-9F
Printable (default). Prints data in the range of hex 80 through hex 9F.
Control Code. Interprets data in the range of hex 80 through hex 9F as a
control code.
130
stop code: >
¬¬
stop code: $
stop code: _