Join Timer — Indicates the amount of time, in centiseconds, that PDUs are transmitted.
The default value is 20 centiseconds.
❏
Leave Timer — Indicates the amount of time lapse, in centiseconds, that the device
waits before leaving its GARP state. Leave time is activated by a Leave All Timer
message sent/received, and is cancelled by a Join message received. Leave Timer must
be greater than or equal to three times the Join Timer. The default value is 60
centiseconds.
❏
Leave All Timer — Indicates the amount of time lapse, in centiseconds, that all devices
wait before leaving the GARP state. The Leave All Timer must be greater than the Leave
Timer. The default value is 1000 centiseconds.
2. Click
GARP Parameter Settings
3. Modify the Interface, Join Timer (centiseconds), Leave Timer (centiseconds), and Leave
All Timer (centiseconds) fields.
4. Click
Embedded Web System User Guide
. The GARP Parameter Settings page opens:
. The GARP parameters are defined, and the device is updated.
www.hp.com
Configuring Interfaces
6-17