Wireless Channel Monitor

5-4

Wireless Channel Monitor

5-4-1

Method without configurator

Preparation
Test procedure
Obtains the receiving wave level of the frequency band (all channels) to allow
for the selection of the available channels (frequency band).
• The DeviceNet master and DeviceNet slave do not need to be connected
for the positioning test.
• Prepare either the wireless master station or an slave station. (Either one
is acceptable.)
• The wireless unit requires a communication power supply. Connect the
unit to the power via the DeviceNet cable prepared for a micro-connector.
SW2
W CH
RUN
TEST
X10
X1
SET
SW3
ON
1 2
3 4
5
7 8
6
MS
NS
WS
N NODE
SW2
RUN
TEST
X10
X1
SET
SW1
ON
1 2
3 4
Master station
MS
NS
WS
N NODE
SW2
RUN
TEST
X10
X1
SET
SW1
ON
1 2
3 4
W NODE
X10
X1
SW2
W CH
RUN
TEST
X10
X1
SET
SW3
ON
1 2
3 4
5
6
7 8
1. Set the mode select switch to
"TEST".
Set SW3 to "bit 3 = ON".
Set the WCH switch to the wireless
channel to be monitored. "01" is
used for this example.
2. Turn on the communication power
supply. The system is in test opera-
tion status. The NS LED goes off
and the MS LED flashes green.
3. The WS LED lights green and the
LED display shows the receiving
wave level "L1 to L9".
4. Set the WCH switch of the wireless
master station to the wireless chan-
nel to be monitored next, and then
push SW2.
Repeat this procedure to search the
available channel whose receiving
wave level is "L1"or lower. Select the
wireless channel to be used among
the unused channels.
Section 5-4