4. If this window disappears and the following window is displayed, the serial
numbers have been successfully written.
If there were some wireless slave stations for which the serial number
could not be written (e.g., because communications were not possible),
those wireless slave stations are displayed in the way shown below.
After taking any steps necessary to restore communications with the wire-
less slave stations (e.g., by making switch settings), click the "Write Serial
No." button again.
• You can acquire the receiving wave level for the frequency bands used (all
channels) to select a channel (frequency band) that can be used.
• You can log all channels or the temporal variation in the receiving wave
level of a specified channel.
• While monitoring all channels, you can display a bar graph with the
receiving wave level along the vertical axis and the wireless channels
along the horizontal axis, with the current values and maximum values for
each channel.
• While monitoring a single channel, you can display a broken line graph
with the receiving wave level along the vertical axis and the time along the
horizontal axis.
• The monitoring results can be saved as CSV files on the computer.