Wireless Network Parameter Editing

8-3

Wireless Network Parameter Editing

8-3-1

Setting procedure flow

8-3-2

Setting procedure

Wireless slave station
registration
1,2,3...
112
This section covers the setting procedures for wireless network configuration
parameters, such as wireless slave station registration.
The procedure for setting wireless network parameters is shown below.
Wireless slave station registration
Routing path settings (* only required when setting relay stations)
Writing to the device (wireless master station)
Resetting the wireless master station
The wireless slave station to be registered on the wireless network should be
registered on the wireless master station.
1. Set the wireless master station "mode select switch" to RUN.
2. Select the wireless master station to which the wireless slave station is to
be registered from the "Network Configuration" window on the DeviceNet
configurator.
3. Select "Edit Device Parameters" from "Edit" on the menu bar.
Depending on the type of wireless master station used, one of the following
screens is displayed.
If the wireless master station is a WD30-M or a WD30-ME, the following
screen is displayed.