Examples Of Wiring For Each Application; Emergency Stop Switch Dual Channel Inputs With Manual Reset; Two-Hand Input - Omron DEVICENET SAFETY - 04-2005 Operation Manual

Safety i/o terminals
Table of Contents

Advertisement

7-2

Examples of Wiring for Each Application

7-2-1

Emergency Stop Switch Dual Channel Inputs with Manual Reset

An example of the wiring and configuration when using the DST1-ID12SL-1 is shown below.
Wiring
V
G
E1
GND
Configuration
Parameter
group
Safety Input 0 0008
Safety Input 1 0012
Safety Input 11 0052
Test Output 0 0001
Test Output 1 0002
Test Output 2 0003
7-2-2

Two-Hand Input

An example of the wiring and configuration when using the DST1-ID12SL-1 is shown below.
Wiring
V
G
E1
G N D

7-2 Examples of Wiring for Each Application

IN0
IN1
T0
T1
11
21
12
22
S1
Parameter name
Safety Input 0 Channel Mode
0009
Safety Input 0 Test Source
0054
Dual Channel Safety Input 0/1 Mode
0055
Dual Channel Safety Input 0/1 Discrepancy Time 100 x 10 ms
Safety Input 1 Channel Mode
0013
Safety Input 1 Test Source
Safety Input 11 Channel Mode
0053
Safety Input 11 Test Source
0064
Dual Channel Safety Input 10/11 Mode
Test Output 0 Mode
Test Output 1 Mode
Test Output 2 Mode
IN0
IN1
T0
T1
S 11
IN
T2
E1: 24-V DC Power Supply (S8@@)
11
S1: Emergency Stop Switch (A165E or
T1
G
A22E) (positive opening mechanism)
S2: Reset switch
S2
E1: 24-V DC Power Supply (S8@@)
IN2
IN3
S11,S12: Two-hand control switches
T0
T1
S 12
Value
Test pulse from test output
Test Output 0
Dual Channel Equivalent
Test pulse from test output
Test Output 1
Used as standard input
Not Used
Single Channel
Pulse Test Output
Pulse Test Output
Power Supply Output
81