Receiving (Uploading) Data
Reference: S When the Support Tool receives data from a PT, the data being edited at the
Data Type
*1
System Memory
*2
Table
*1:
With the NT21, NT31, NT31C, NT631 and NT631C, individual transmission
of system memory is restricted as follows:
The following data stored in the Support Tool can not be overwritten.
S Number of numeral table entries
S Number of string table entries
S Number of bit memory table entries
S Screen history setting
S Alarm history setting
S Numeral storage type
The following data can be overwritten.
S Initial screen number
S Screen data comment
*2:
It is not possible to perform individual transmission of the mathematical
table. The mathematical table will be transmitted only when application
transmission is performed.
Support Tool is lost. Therefore, make sure that the edit data is saved in a file
before executing data receiving from the PT to the Support Tool.
S With the NT21, NT31, NT31C, NT631, and NT631C, individual uploading of
tables is possible. However, it may take time to upload the bit memory table. In
this case, perform batch transmission of the application (in file units).
Description
The contents of "System" set at the PT are re-
ceived and set for "System" of "PT Configura-
tion."
NT20, NT20S and NT600S:
The following data is received in a batch.
S Numeral memory table data
S Character string memory table (String table)
data
S Mark data
NT21, NT31, NT31C, NT631, and NT631C:
The following data can be received individually.
S Numeral memory table data
S Character string memory table (String table)
data
S Bit memory table data
S Mark data
S Image data
S Library data
S Recipe table
Section
11-4