Omron CQM1H-SCB41 Operation Manual page 312

Sysmac cqm1h series serial communications board
Hide thumbs Also See for CQM1H-SCB41:
Table of Contents

Advertisement

K3T@ Intelligent Signal Processor Protocol
Read Set Value with Bank (by Unit Number) (Sequence No. 322)
Reads the set value of a bank which is not in use (K3TR: HH to LL, K3TC:01 to 05) and stores the results in the
specified words.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Receive Data Word Allocation (3rd Operand of PMCR)
Receive data
storage words
Number of send data words
+0
(Undefined)
+1
Number of units
(Undefined)
Relevant unit No.
+2
(Undefined)
+3
Operand
+4
~
+95
(Undefined)
Relevant unit No.
+96
(Undefined)
+97
Operand
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Number of units (2 digits BCD)
+2
Relevant unit No. (2 digits BCD)
+3
Bank No. (2 digits BCD)
+4
Operand (ASCII 2 characters)
+ 97
Operand (ASCII 2 characters)
+0
Number of receive data words
Set value
+1
(Undefined)
+2
~
+63
Set value
(Undefined)
+64
Offset
Contents (data format)
+0
Number of receive data words
(4 digits BCD)
+1 to +2 Set value
(5 digits BCD)
+63 to
Set value
+64
(5 digits BCD)
Bank No.
~
Bank No.
0005 to 0098
01 to 32
00 to 99
01 to 04
4848 ("HH"),
4820 ("H "),
4C20 ("L "),
4C4C ("LL"),
4F35 ("O5")
Same as above
Set value
~
Set value
0003 to 0065
00000 to 99999
Negative sign: F (5th digit BCD)
Example 12345
+1
+2
Same as above
Appendix I
Data
4F31 ("O1")
4F32 ("O2")
4F33 ("O3")
4F34 ("O4")
Data
Example 1234
2345
+1
1234
+2
0001
000F
297

Advertisement

Table of Contents
loading