3Z4L Laser Micrometer Protocol
+30
+31
+32
+33
+34
+35
+36
+37
+38
+39
+40
+41
+42
+43
+44
+45
+46
+47
+48
+49
+50
+51
+52
+53
328
Decimal portion
Integer portion
(Undefined)
Sign
(Undefined)
(Undefined)
(Undefined)
Decimal portion
(Undefined)
Integer portion
Sign
(Undefined)
(Undefined)
(Undefined)
Schedule output timer
Sample measurement pulse
(Undefined)
(Unused)
(Unused)
0
0
0
0
0
0
0
0
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Unused
+2 to +4 Segment number
(ASCII 6 characters)
+5
Measurement interval num-
ber (1 digit BCD)
+6
Lower limit value (decimal
portion)
(4 digits BCD)
+7
Lower limit value (Integer
portion)
(3 digits BCD)
+8
Lower limit value (Sign)
(ASCII 1 character)
+9 to
Upper limit value
+11
+12 to
Multistep selection limit
+14
value (L1)
+15 to
Multistep selection limit
+17
value (L2)
+18 to
Multistep selection limit
+20
value (L3)
+21 to
Multistep selection limit
+23
value (L4)
+24 to
Multistep selection limit
+26
value (L5)
+27 to
Multistep selection limit
+29
value (L6)
+30 to
Reference value
+32
Reference value (REF)
Analog output scale number (SCL)
Offset classification (OF)
Offset value
Data output conditions (PR)
(PRT)
(SMP)
Sample measurement classification
(Undefined)
Setting Yes/No flags
0054 (fixed)
Undefined
Combination of 31('1') to 36('6'), 20(' ')
1 to 4
0000 to 9999
000 to 999
if +: 20(' ')
if –: 2D('–')
Same as lower limit values
Same as lower limit values
Same as lower limit values
Same as lower limit values
Same as lower limit values
Same as lower limit values
Same as lower limit values
Same as lower limit values
Appendix K
Data
Example 123.4567
+6
4 5 6 7
+7
0 1 2 3
+8
2 D 0 0