Omron CQM1H-SCB41 Operation Manual page 409

Sysmac cqm1h series serial communications board
Hide thumbs Also See for CQM1H-SCB41:
Table of Contents

Advertisement

V600/V620 ID Controller Protocol
Note 1. Write data designated for hexadecimal is sent beginning with the largest offset from the send data
words.
2. Always set an even number of digits for the write data.
Write (Hexadecimal/8) (Sequence No. 525)
This sequence is used when the number of Heads to be written to the Carrier is 8. Up to 10 digits of data can
be written for each Read/Write Head.
Send Data Word Allocation (2nd Operand of PMCR)
First word of send
data
394
+0
Number of send data words
Number of Heads
+1
+2
(Undefined)
+3
(Undefined)
+4
Leading address No.
+5
Number of write digits
+6
Write data
~
(Undefined)
+8
+9
Not used
~
+15
Not used
+16
(Undefined)
(Undefined)
+17
Leading address No.
+18
+19
Number of write digits
+20
Write data
~
(Undefined)
+22
~
(Undefined)
+100
+101
(Undefined)
+102
Leading address No.
+103
Number of write digits
+104
Write data
~
+106
(Undefined)
Unit No.
Head CH No.
CH 1
~
Write data
~
Unit No.
Head CH No.
CH 2
~
Write data
~
Unit No.
Head CH No.
CH 8
~
Write data
Appendix M