Using the Programming Console for the First Time
NOT
SET
RESET
• To create one cyclic task only, select 0: ALL.
• To create one cyclic task and one or more interrupt tasks, select INT
1: YES. To create one cyclic task only, select INT 0: NO.
• When creating an interrupt task always select INT 1: YES when clear-
ing memory. If INT 0: NO is selected, you will not be able to create in-
terrupt tasks and it will be necessary to clear memory again using INT
1: YES.
Note The Programming Console cannot be used to create programs with
more than one cyclic task. Use the CX-Programmer if more than one
cyclic task is required.
5. Create an I/O table using the procedure given on page 46. With CS1-se-
ries PLCs, an I/O table must be created.
6. Read/clear error messages.
If an error message is displayed, pressing the MON Key after removing the
cause of the error will clear the error message display. If there are several
error messages, repeat this operation several times.
000000CLR MEM
CHWA TCDE
000000CLR MEM
MON
0:ALL
1:TASK
000000 CLR ALL ?
0
INT 0:NO 1:YES
000000 CLR ALL ?
0
INT 0:NO
000000CLR'G MEM
MON
INT 0:NO
000000 CLR ALL
END 0:NO
000000
FUN
FUN (???)
ERR/MSG
MON
CHK OK