6.
Unscrew the dipstick from the top of the
transaxle and wipe it with a clean rag.
7.
Screw the dipstick into the transaxle and ensure
that it is fully seated.
8.
Unscrew the dipstick and check the fluid level.
Note:
The fluid should be up to top of the flat
portion of the dipstick.
9.
If the level is low, add enough of the specified
fluid to achieve the proper level.
Changing the Hydraulic
Fluid and Cleaning the
Strainer
Service Interval: Every 800 hours
Hydraulic-fluid capacity: 7 L (7.5 US qt)
Hydraulic-fluid type: Dexron III ATF
1.
Park the machine on a level surface, engage the
parking brake, shut off the engine, and remove
the key.
2.
Remove the drain plug from the side of the
reservoir, and let the hydraulic fluid flow into a
drain pan
(Figure
Figure 69
70).
1. Hydraulic reservoir
g002376
3.
Note the orientation of the hydraulic hose and
90° fitting connected to the strainer on the side
of the reservoir
4.
Remove the hydraulic hose and 90° fitting.
5.
Remove the strainer and clean it by back
flushing it with a clean de-greaser.
Note:
Allow it to air dry before installing.
1. Hydraulic strainer
6.
Install the strainer.
7.
Install the hydraulic hose and 90° fitting to the
strainer in the same orientation.
8.
Install and tighten the drain plug.
9.
Fill the reservoir with approximately 7 L (7.5
US qt) of the specified hydraulic fluid; refer to
Checking the Transaxle/Hydraulic-Fluid Level
(page
56).
10.
Start the engine and operate the machine to fill
the hydraulic system.
57