Inspecting Fuel Lines and
Connections
Service Interval: Every 400 hours/Yearly (whichever
comes first)
Inspect the fuel lines, fittings, and clamps for signs of
leaking, deterioration, damage, or loose connections.
Note:
Repair any damaged or leaking fuel system
component before using the machine.
Electrical System
Maintenance

Electrical System Safety

CALIFORNIA
Proposition 65 Warning
Battery posts, terminals, and related
accessories contain lead and lead
compounds, chemicals known to
the State of California to cause
cancer and reproductive harm. Wash
hands after handling.
Disconnect the battery before repairing the
machine. Disconnect the negative terminal first
and the positive last. Connect the positive terminal
first and the negative last.
Charge the battery in an open, well-ventilated
area, away from sparks and flames. Unplug the
charger before connecting or disconnecting the
battery. Wear protective clothing and use insulated
tools.

Servicing the Fuses

The fuses for the electrical system are located under
the center of the dash panel
1. Fuses
43
WARNING
(Figure 40
and
Figure 40
Figure
41).
g010328