Parameter Settings - Panasonic FP7 User Manual

Multi input/output unit
Hide thumbs Also See for FP7:
Table of Contents

Advertisement

10.5 Positioning Table Settings (Configurator PMX)
● When interpolation control is selected, the data table is changed to the channel numbers for the
X and Y axes, and ["Interpolation"] is displayed on the tab.

10.5.2 Parameter Settings

Use the Configurator PMX to allocate the most fundamental parameters for positioning control,
such as the motor rotation direction, pulse output method (CW/CCW and Pulse/Sign), home
input, limit input logic, and positioning control. The following procedure is explained on the
condition that the Configurator PMX has already started.
For the procedure of activating Configurator PMX, refer to
Parameters
Parameter name
Pulse output method
Pulse output rotation
direction
Startup Speed
Positioning repeat count
Home position logic
Near home input logic
Limit + switch logic
Limit - switch logic
10-22
Default (Unit)
Settings
Pulse/Sign
Pulse/Sign, CW/CCW
When selecting Pulse/Sign mode:
CW direction +: Select this setting for the case that the elapsed
value is plused when Sign output turns off.
CCW direction +: Select this setting for the case that the
elapsed value is plused when Sign output turns on.
CW direction +
When selecting CW/CCW mode:
CW direction +: Select this setting for the case that the elapsed
value is plused at the time of CW output.
CCW direction +: Select this setting for the case that the
elapsed value is plused at the time of CCW output.
Set the startup speed common to each operation. This setting
is common to JOG operation, home return, E-point control, P-
100 (pps)
point control, C-point control and J-point control.
Setting range: 1 to 500,000
Specify this setting for performing repetitive controls when
using E-point/P-point/C-point control.
0, 1: Not repeat
0
2 to 254: Repeat for the specified number of times.
255: Repeat infinitely until the execution of stop control.
Normal Open
Normal Open
Select the input logic for each switch.
Normal Open、Normal Close
Normal Open
Normal Open
""10.5.1 Used Channel
WUME-FP7MXY-06
Setting"".

Advertisement

Table of Contents
loading

This manual is also suitable for:

Afp7mxy32dwdAfp7mxy32dwdh

Table of Contents