8.2 Execution Example of Comparison Output Function

8.2 Execution Example of Comparison Output Function

8.2.1 Comparison Output of Counter for External Input

Overview
This function is used for comparing the elapsed value of the high-speed counter CH0 for
external inputs to ""Comparison output setting value"" specified in advance, and turning on the
comparison output (CMP0: output number Y100) when the comparison condition is met.
Configuration
● Allocate high-speed counter inputs to the inputs (X100-X103), and select ""Direction
distinction"".
● Select ""Comparison match output"" in the function selection tree, and double-click the
comparison match number CMP0 to open the "Advanced" dialog box.
● Select ""High-speed counter CH0"" as a counter to be compared. Also, select ""ON when
elapsed value is larger than or equal to setting value"" for the comparison output function,
and input a comparison value.
8-6
WUME-FP7MXY-06