ES-2108 Series User's Guide
Table 26 Bandwidth Control (continued)
LABEL
*
Active
Ingress Rate
Active
Egress Rate
Apply
Cancel
108
DESCRIPTION
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row
first to set the common settings and then make adjustments on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you
make them.
Make sure to select this check box to activate ingress limits on a port.
Specify the maximum bandwidth allowed in Kilobits per second (Kbps) for the incoming
traffic flow on a port.
If you enter a number between 64 and 1728, the switch automatically rounds the
number down to the nearest multiple of 64.
If you enter a number between 1729 and 1999, the rate is fixed at 1792.
If you enter a number between 2000 and 103999, the switch rounds the number down
to the nearest multiple of 1000.
On a Gigabit Ethernet/ Mini-GBIC port, the switch rounds a number down to the
nearest multiple of 8000 for a number between 104000 and 1000000.
Make sure to select this check box to activate egress limits on a port.
Specify the maximum bandwidth allowed in Kilobits per second (Kbps) for the out-
going traffic flow on a port.
If you enter a number between 64 and 1728, the switch automatically rounds the
number down to the nearest multiple of 64.
If you enter a number between 1729 and 1999, the rate is fixed at 1792.
If you enter a number between 2000 and 103999, the switch rounds the number down
to the nearest multiple of 1000.
On a Gigabit Ethernet/ Mini-GBIC port, the switch rounds a number down to the
nearest multiple of 8000 for a number between 104000 and 1000000.
Click Apply to save your changes to the switch's run-time memory. The switch loses
these changes if it is turned off or loses power, so use the Save link on the top
navigation panel to save your changes to the non-volatile memory when you are done
configuring.
Click Cancel to reset the fields to your previous configuration.