2 - Standard Protections

55 | © 2023 ABB | 1SDH001330R1002 - ECN000297030
List The Standard protections available for all Ekip Touch models, are:
Name
Type of protection
L
Overload with inverse long-time delay
S
Selective short-circuit
S2
Short-circuit with adjustable delay
I
Instantaneous short-circuit
G
Earth fault with adjustable delay
(1)
MCR
Instantaneous short-circuit on circuit-breaker closing
2I
Instantaneous short-circuit programmable
IU
Current unbalance
Neutral
Different protection on neutral phase
Harmonic
Distorted waveforms
distortion
T
Abnormal temperatures
Hardware Trip
Internal connection errors
linst
(2)
Instantaneous short-circuit at high currents
not available with LSI version of Ekip Touch
(1)
(2)
protection cannot be deactivated; its trip parameters are set by ABB and cannot be edited