Lenovo 7DCE Messages Manual page 56

Hide thumbs Also See for 7DCE:
Table of Contents

Advertisement

This message is for the use case when an implementation has detected a Front Panel NMI / Diagnostic
Interrupt.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0222
User Action:
If the NMI button has not been pressed, complete the following steps:
1. Reboot the system.
2. If error still exist, then collect serivce log and contact Lenovo support.
• FQXSPIO0004L: A bus timeout has occurred on bus [SensorElementName].
This message is for the use case when an implementation has detected a Bus Timeout.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0224
User Action:
Complete the following steps:
1. Update the firmware (UEFI&XCC) to the latest level.
2. Please reseat the processor and reboot the server.
3. If the problem still exist, (service technician) please replace the system board.
4. If the problem still exist, contact Lenovo support.
• FQXSPIO0006N: A software NMI has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a Software NMI.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0228
User Action:
Check the event log in system event log to resolve any issues related the NMI
• FQXSPIO0007N: A PCI PERR has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a PCI PERR.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
52
ThinkSystem ST250 V3 Messages and Codes Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem st250 v37dcf

Table of Contents