Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0140
User Action:
Information only; no action is required.
• FQXSPMA0024G: Sensor [SensorElementName] has asserted.
This message is for the use case when an implementation has detected a Sensor has asserted.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Memory
SNMP Trap ID: 43
CIM Prefix: PLAT CIM ID: 0508
User Action:
Complete the following steps:
1. If the DIMM configuration was changed prior to this failure verify that the DIMMs are installed in the
correct population sequence.
2. RESEAT the DIMM that failed POST memory test and the DIMMs on adjacent slots if populated. Boot
to F1 setup and enable the DIMM. Reboot the system.
3. If the DIMMs have been upgraded just prior to the issue than update uEFI to the latest version.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
• FQXSPMA0025I: Sensor [SensorElementName] has asserted.
This message is for the use case when an implementation has detected a Sensor has asserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0508
User Action:
Information only; no action is required
• FQXSPMA2007I: Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName] has recovered.
This message is for the use case when an implementation has detected a Memory Scrub failure recovery.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Memory
SNMP Trap ID: 41
CIM Prefix: PLAT CIM ID: 0137
User Action:
.