Lenovo 7DCE Messages Manual page 44

Hide thumbs Also See for 7DCE:
Table of Contents

Advertisement

This message is for the use case when an implementation has detected that a Sensor has deasserted a
transition to non-critical from normal.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0521
User Action:
Use storcli or LSA to check if there is any warning or critical RAID event.
• FQXSPEA2002I: Sensor [SensorElementName] has transitioned to a less severe state from critical.
This message is for the use case when an implementation has detected a Sensor transition to less severe
from critical.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0523
User Action:
Use Storcli, LSA, arcconf, or Maxview to check if there is any warning or critical RAID event.
• FQXSPEA2003I: Link up is detected on port [arg1] of the PCIe device [arg2].
This message is for the use case when an implementation has detected that a link up of PCIe.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0521
User Action:
Information only; no action is required
• FQXSPEM4000I: The [arg1] on system [arg2] cleared by user [arg3].
This message is for the use case where a Management Controller Event Log on a system is cleared by a
user.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0020
User Action:
Information only; no action is required.
• FQXSPEM4001I: The [arg1] on system [arg2] is 75% full.
40
ThinkSystem ST250 V3 Messages and Codes Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinksystem st250 v37dcf

Table of Contents