User Action:
Information only; no action is required
• FQXSPPW0002L: [PowerSupplyElementName] has Failed.
This message is for the use case when an implementation has detected a Power Supply has failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0086
User Action:
Please check the event log in XClarity Controller (XCC) Web GUI to identify the power supply unit failure.
1. Check the system spec, and replace the power supply unit with another unit of the same wattage.
• FQXSPPW0003G: Failure predicted on [PowerSupplyElementName].
This message is for the use case when an implementation has detected a Power Supply failure is
predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID: 164
CIM Prefix: PLAT CIM ID: 0088
User Action:
Please check the event log in XClarity Controller (XCC) Web GUI to identify the power supply unit failure.
• FQXSPPW0005I: [PowerSupplyElementName] is operating in an Input State that is out of range.
This message is for the use case when an implementation has detected a Power Supply that has input out
of range.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0098
User Action:
Information only; no action is required
• FQXSPPW0006I: [PowerSupplyElementName] has lost input.
This message is for the use case when an implementation has detected a Power Supply that has input
that has been lost.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID:
.
Chapter 2