3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.
• FQXSPPU2000I: [ProcessorElementName] in slot [SlotElementName] has been removed.
This message is for the use case when an implementation has detected a Processor has been Removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0035
User Action:
Information only; no action is required.
• FQXSPPU2001I: An Over-Temperature Condition has been removed on [ProcessorElementName].
This message is for the use case when an implementation has detected a Over-Temperature Condition
has been Removed for Processor.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0037
User Action:
Information only; no action is required
• FQXSPPU2002I: The Processor [ProcessorElementName] is no longer operating in a Degraded
State.
This message is for the use case when an implementation has detected a Processor is no longer running
in the Degraded state.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - CPU
SNMP Trap ID: 42
CIM Prefix: PLAT CIM ID: 0039
User Action:
Information only; no action is required
• FQXSPPW0001I: [PowerSupplyElementName] has been added to container
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Power Supply has been added.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0084
96
ThinkSystem ST250 V3 Messages and Codes Reference