3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFDD0012I: SATA Hard Drive Error: [arg1] was recovered.
Severity: Info
Parameters:
[arg1] Slot/bay label name in system
User Action:
Information only; no action is required.
• FQXSFDD0012K: SATA Hard Drive Error: [arg1].
Severity: Error
Parameters:
[arg1] Slot/bay label name in system
User Action:
Complete the following steps:
1. Power down the server.
2. Re-insert SATA Drive to ensure it is fully connected to the backplane.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0011M: A PCIe parity error has occurred on Bus [arg1] Device [arg2] Function [arg3]. The
Vendor ID for the device is [arg4] and the Device ID is [arg5]. The Physical slot number is [arg6].
Severity: Error
Parameters:
[arg1] Bus
[arg2] Device
[arg3] Function
[arg4] VID
[arg5] DID
[arg6] Instance number
User Action:
Complete the following steps:
1. Check Lenovo Support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver and
any required firmware updates.
2. If this node and/or any attached cables were recently installed, moved, serviced or upgraded.
a. Reseat Adapter and any attached cables.
b. Reload Device Driver.
c. If device is not recognized, reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2
settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports ->PCIe
Gen1/Gen2/Gen3 Speed Selection, or the OneCLI utility.
d. If a PCIe error has also been reported on a second slot within the same node, ensure steps a, b,
and c above are also performed for that adapter before proceeding.