Standard Torques For Collar Clamps; Standard Torques For Pipe Clamps According To Din 3015 - Kohler KD62V12A Operation And Maintenance Manual

Table of Contents

Advertisement

Appendix
Standard tightening torques
Size
15L
18L
22L
28L
35L
42L
Tab. 79: Alternative tightening torques for DKO connectors

8.4.12 Standard torques for collar clamps

Fig. 144: Collar clamp
Band width
18 mm (0.71 in)
20 mm (0.79 in)
25 mm (0.98 in)
30 mm (1.18 in)
Tab. 80: Tightening torques for collar clamps according to DIN 3017-3

8.4.13 Standard torques for pipe clamps according to DIN 3015

Fig. 145: Pipe clamps
236
Equivalent specification
70 Nm (52 ft-lb)
90 Nm (66 ft-lb)
120 Nm (89 ft-lb)
160 Nm (118 ft-lb)
250 Nm (184 ft-lb)
380 Nm (280 ft-lb)
© 2023 by Kohler Co. All rights reserved.
Size
Equivalent specification
14S
75 Nm (55 ft-lb)
16S
85 Nm (63 ft-lb)
20S
140 Nm (103 ft-lb)
25S
190 Nm (140 ft-lb)
30S
270 Nm (199 ft-lb)
38S
400 Nm (295 ft-lb)
Tightening torque
4 Nm (3 ft-lb)
7 Nm (5 ft-lb)
12 Nm (9 ft-lb)
30 Nm (22 ft-lb)
KD62V12A 33521061401_1_1 EN_US
2023-10

Advertisement

Table of Contents
loading

Table of Contents